Lecroy WAVEACE 2022 2-channel oscilloscope, Digital Storage oscilloscope, WaveAce 2022 Manuale Utente

Codici prodotto
WaveAce 2022
Pagina di 89
WaveAce Remote Control 
 
58 
920836 Rev A  
STATUS - DDR? 
Description 
The DDR? query reads and clears the contents of the Device Dependent or device specific error 
Register (DDR). In the case of a hardware failure, the DDR register specifies the origin of the 
failure. The following table provides details. 
Query Syntax 
DDR? 
Response Format 
DDR <value> 
<value>:= 0 to 65535 
DDR? Status Register Structure 
Bit 
Value 
Description 
15...14 
  
0 - Reserved. 
13 
8192 
1 - Timebase hardware failure detected. 
12 
4096 
1 - Trigger hardware failure detected. 
11 
2048 
1 - Channel 4 hardware failure detected. 
10 
1024 
1 - Channel 3 hardware failure detected. 
512 
1 - Channel 2 hardware failure detected. 
256 
1 - Channel 1 hardware failure detected. 
128 
1 - External input overload condition detected. 
6...4 
  
0 - Reserved. 
1 - Channel 4 overload condition detected. 
1 - Channel 3 overload condition detected. 
1 - Channel 2 overload condition detected. 
1 - Channel 1 overload condition detected.