Axis 207MW 0264-004 Manuale Utente

Codici prodotto
0264-004
Pagina di 73
AXIS 207/207W/207MW Installation Guide
Page 5
ENGLISH ENGLISH
Unit connectors
Network connector -  RJ-45 Ethernet connector. Supports Auto-MDIX (AXIS 207W/MW 
only) for automatic detection of straight or crossover cable. Using shielded cables is 
recommended.
Power connector - Mini DC connector. 4.9-5.1V DC, max 4.0W. See product label for 
±
 
connection.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, 
time lapse recording, alarm notifications, etc. It provides the interface to: 
• 1 transistor output - For connecting external devices such as relays and LED:s. 
Connected devices can be activated by Output buttons on the Live View page or 
by an Event Type. The output will show as active (in Event Configuration > Port 
Status
) if the alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between 
an open and closed circuit, for example: PIRs, door/window contacts, glass break 
detectors, etc. When a signal is received the state changes and the input becomes 
active (shown under Event Configuration > Port Status).
• Auxiliary power and GND
Function Pin 
number
Notes
Specifications
Transistor 
Output
Pin 4
Uses an open-collector NPN 
transistor with the emitter con-
nected to the GND pin. If used 
with an external relay, a diode 
must be connected in parallel 
with the load, for protection 
against voltage transients.
Max load = 100mA
Max voltage = 24V DC 
(to the transistor)
Digital Input
Pin 3
Connect to GND to activate, or 
leave floating (or unconnected) 
to deactivate.
Must not be exposed to 
voltages greater than 
10V DC
GND
AXIS 207 = Pin 2
AXIS 207W/MW = Pin 1
Ground
Auxiliary DC 
Power Input
AXIS 207 = Pin 1
AXIS 207W/MW = Pin 2
Electrically connected in parallel 
with the connector for the power 
supply, this pin provides an 
auxiliary connector for mains 
power to the unit. 
This pin can also be used to 
power auxiliary equipment, with 
a maximum current of 50mA.
Voltage = 4.9-5.1V DC
(all models)
Min power:
AXIS 207: 2.5W
AXIS 207W: 3.5W
AXIS 207MW: 4.0W
Pin layouts
1
4
1
4
AXIS 207MW
AXIS 207W
AXIS 207