Ultralife ER26500M, C Size 6500mAh Lithium Battery Cell 3.6V ER26500M Scheda Tecnica

Codici prodotto
ER26500M
Pagina di 5
 
 
- Page 2/5 -
                                                                        MSDS Li-SOCl
Rev 2.Dec.2004
 
 
Do not expose the batteries to temperatures above 100°C. If the battery lose its integrity 
and sealing, due to break or damages (mechanical, thermal or electrical), leakage, 
explosion or fire may follow. 
In this case there is the risk of release of chemical materials as defined in the paragraph 2 
(active materials) of this safety sheet. 
Here below are shown the nature of special risks and the advices of caution. 
 
Nature of special risks 
 R14/15 (reacts with water and yields flammable gases) 
 R21 (harmful in contact with skin) 
 R22 (harmful if swallowed) 
 R35 (causes severe burns) 
 R41 (risk of serious damage to the eye) 
 R42/43 (may cause sensitation by inhalation and skin contact)  
 
Safety advices 
 
 
S2  (keep out of reach from children)  
S8  (keep away from moisture) 
S22 (do not breathe dust) 
S24 (avoid contact with skin) 
S26 (in case of contact with eyes, rinse immediately with plenty of water and seek medical 
attention) 
S36 (wear suitable protective clothing) 
S37 (wear suitable gloves) 
S43 (in case of fire use extinguisher type D. DO NOT USE WATER) 
S45 (in case of incident or indisposition seek medical attention) 
 
4. First aid measures 
 
Only in case of contact with internal componets of the battery: 
 
Skin contact:     flush with plenty of water 
Eye contact:      flush with plenty of water (eyelids held open)  
Inhalation: 
    breath fresh air and give oxygen or artificial respiration by specialist people 
Ingestion:         drink much water and consult a doctor 
 
5. Fire-fighting measures 
 
Extinguishing media: 
extintinguishers type D, Lith-X, DO NOT USE WATER in case  
  
of battery leakage 
 
Special hazards: 
 
irritating vapour 
 
Special protective 
equipment: 
  wear protective clothing, use self-contained breathing apparatus                 
 
  with filtered cartridge type ABEK 
 
6. Accidental release measures