Testboy TV 455VDE-tester Testboy TV 455 Manuale Utente

Codici prodotto
Testboy TV 455
Pagina di 76
TESTBOY TV 450 
Appendix C
 
 
74 
Time delayed RCDs demonstrate delayed response characteristics. They contain 
residual current integrating mechanism for generation of delayed trip out. However, 
contact voltage pre-test in the measuring procedure also influences the RCD and it 
takes a period to recover into idle state. Time delay of 30 s is inserted before performing 
trip-out test to recover 
S
 type RCD after pretests and time delay of 5 s is inserted for 
the same purpose for 
G
 type RCD. 
 
Modification of the chapter 5.4.1 
 
RCD type 
Contact voltage Uc  
proportional to 
Rated 
I
ΔN
 
 
AC 
G
 
1.05
×I
ΔN
 
AC 
S
 
2
×1.05×I
ΔN
 
any 
G
 
1.4
×1.05×I
ΔN
 
S
 
2
×1.4×1.05×I
ΔN
 
≥ 30 mA
G
 
2
×1.05×I
ΔN
 
S
 
2
×2×1.05×I
ΔN
 
< 30 mA
Both models 
 
2
×1.05×I
ΔN
 
S
 
2
×2×1.05×I
ΔN
 
any 
Model TESTBOY TV 450 (Type B) 
only 
Table C.1: Relationship between Uc and I
ΔN
 
Technical specifications remain the same.