Testboy TV 455VDE-tester Testboy TV 455 Manuale Utente
Codici prodotto
Testboy TV 455
TESTBOY TV 450
Quick-test guide
10
2 Quick-test guide
2.1 Null the leads
Starting the tester:
1. Insert the fully charged batteries
2. Press the On/Off button
3. Connect test cable to the
2. Press the On/Off button
3. Connect test cable to the
instrument.
1
Step
Select Continuity function (R LOWΩ or
CONTINUITY*) with the function selector switch
first. The following menu is displayed:
CONTINUITY*) with the function selector switch
first. The following menu is displayed:
2
Step
Short test leads first as shown.
N/L2
L/L1
L/L1
PE/L3
N/L2
PE/L3
prolongation lead
3
Step
Press the TEST key in order to perform regular measurement. Result
close to 0.00 Ω is displayed.
close to 0.00 Ω is displayed.
4
Step
Press the CAL key. After performing test leads compensation first measured
value and then 0.00 Ω is displayed. If calibration was carried out successfully
leads indicator
value and then 0.00 Ω is displayed. If calibration was carried out successfully
leads indicator
CAL
is shown in R LOWΩ and CONTINUITY* menus.
Measured value to be calibrated.
Reading at calibrated value is
0.00 Ω now.
* The CONTINUITY subfunction is available in model TESTBOY TV 450 (Type B).