Codici prodotto
M817S
5-3
CH 5/ Start Menu
Section A
Automatic Setup
Overview
Automatic Setup
procedure
procedure
Automatic Setup is a one-stop process using pre-defined settings to set the unit
automatically. Users have the option to view the list of parameter settings, change
probe types if current will be monitored, and/or proceed directly with data monitoring.
Follow these steps to perform Automatic Setup.
Continued on next page
Action...
Result...
STEP 1: From the Start Menu,
press Automatic Setup. The auto-
configured circuit type, nominal
voltage, current and frequency
values appear on screen. Data
card status and available space in
card are also displayed.
• To continue Automatic Setup
and begin data monitoring,
press OK. Proceed to Step 2.
• To view the list of parameter
settings for Automatic Setup,
press Summary. Proceed to
Step 3 on page 5-4.
• To display/change probe types
for current monitoring, press
Probe
Probe
. Proceed to Step 4 on
page 5-4.
• Press Cancel to quit and return
to Start Menu.
EP101
STEP 2: The Monitoring Menu
screen allows users to begin
monitoring immediately or at a
specified time and date.
• To start monitoring, press Start
Now!
Proceed to Section C Monitor
Same Circuit - Turning
Monitoring On/Off on page 5-24.
MARK123b