Axis 243SA 0256-004 Manuale Utente

Codici prodotto
0256-004
Pagina di 87
 
32 
AXIS 243SA - Event configuration
Event configuration
This section describes how to configure AXIS 243SA for alarm handling. Various actions 
can be configured to run when certain types of events occur.
Event servers
Event Servers are used for receiving uploaded image files and/or notification messages. To 
set up an Event server for your AXIS 243SA, go to Setup > Event Configuration > Event 
Servers and enter the required information according to the selected server type.
For details on each setting, please refer to the online help
available from each web 
page.
Note: 
The images in pre-trigger and post-trigger buffers will be lost if the connection to the event server fails.
When the setup is complete, the connection can be tested by clicking the Test button (the 
test takes approximately 10 seconds). 
Event type
A set of parameters describing how and when the video server is to perform certain actions
Triggered Event (see page 33)
- the circumstances that start an event
Example: at a signal from an external device, such as a 
door switch or a motion sensor
Scheduled Event (see page 34) - the circumstances that start an event
Example: at a pre-programmed time
Server type
Purpose
Information required
FTP Server
• receives uploaded images
• Descriptive name of your choice
• Network address (IP address or host name)
• User Name and Password (to FTP server)
• Port number
HTTP Server
• receives notification messages
• receives uploaded images
• Descriptive name of your choice
• URL  (address)
TCP Server 
• receives notification messages
• Descriptive name of your choice
• Network address (IP address or host name)
• Port number