Axis 243SA 0256-004 Manuale Utente

Codici prodotto
0256-004
Pagina di 87
 
37 
AXIS 243SA - Event configuration
Please use the online help
for descriptions of each available option.
Examples: 
• Avoid triggering on small objects in the image by selecting a high 
size level.
• To trigger motion detection as long as there is activity in the area, select a high 
history level.
• To only detect flashing light, low 
sensitivity can be selected. In other cases, a high sensitivity level is 
recommended.
Port status
Under Event Configuration > Port Status, there is a list that shows the status for the 
connected inputs and outputs of the Axis video server. This is for the benefit of an 
operator, who cannot access the System Options section.
Example: 
If the Normal state for a push button connected to an input is set to Open circuit, as long as the button 
is not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.
Parameter
Object 
Size
History
Sensitivity
High
Only very large objects 
trigger motion detection
An object that appears in the region will 
trigger the motion detection for a long 
period
Ordinary colored objects against ordinary 
backgrounds will trigger the motion 
detection
Low
Even very small objects 
trigger motion detection
An object that appears in the region will 
trigger motion detection for only a very 
short period
Only very bright objects against a dark 
background will trigger motion detection
Default values Low
Medium to High
Medium to High