AXIS 221 - Unit Connectors
Unit Connectors
This section describes the following:
• The I/O Terminal connector
• Power connections
• The RS-232 D-Sub connector
I/O Terminal connector
The 10-pin I/O terminal connector provides the interface to a solid state relay output, two 
digital photo-coupled inputs, RS-485, GND and auxiliary power.
The terminal connector is used in applications for e.g. motion detection, event triggering, 
time lapse recording, alarm notification via e-mail, image storage to FTP locations, etc.
• Input - Used for connecting external alarm devices and triggering images for 
specific alarm-based events. The input is typically connected to a motion detector 
or any other external security device, and images can be uploaded whenever the 
detector is activated. Maximum 18V DC is allowed on the input.
• Output - This can drive a maximum load of 50V DC at 100mA directly or heavier 
loads by connecting additional relay circuitry. If the output is used with an exter-
nal relay, a diode must be connected in parallel with the load for protection 
against any voltage transients.
Caution!
Connecting AC to the inputs/outputs will damage the unit.
 
10-pin I/O Terminal connector
1 2 3 4 5 6 7 8 9 10
connector 
Power
block
connector 
Power adapter
RS-232 connector
(including RS-485)
AC   AC
GND DC+
Connect DC power (7-24V) on pins 1 and 2.
Connect AC power (10-24V) on pins 2 and 3.