Panasonic ALDP105 PCB Mount Relay ALDP105 Scheda Tecnica
Codici prodotto
ALDP105
LD-P (ALDP)
2
ds_61B10_en_ldp: 260313D
RATING
1. Coil data
2. Specifications
Notes:
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Wave is standard shock voltage of
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Wave is standard shock voltage of
1.250s according to JEC-212-1981
*3 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in
.
Nominal coil
voltage
Pick-up voltage
(at 20
C
68
F
)
Drop-out voltage
(at 20
C
68
F
)
Nominal operating
current
[
10%] (at 20C
68
F
)
Coil resistance
[
10%] (at 20C
68
F
)
Nominal operating
power
Max. allowable voltage
(at 20
C
68
F
)
5V DC
75%V or less of
nominal voltage
nominal voltage
(Initial)
5%V or more of
nominal voltage
nominal voltage
(Initial)
40.0mA
125
200mW
130%V of
nominal voltage
6V DC
33.3mA
180
9V DC
22.2mA
405
12V DC
16.7mA
720
18V DC
11.1mA
1,620
24V DC
8.3mA
2,880
Characteristics
Item
Specifications
Contact
Arrangement
1 Form A
Contact resistance (Initial)
Max. 100 m
(By voltage drop 6 V DC 1A)
Contact material
AgNi type
Rating
Nominal switching capacity (resistive load)
5A 277V AC
Max. switching power (resistive load)
1,385VA
Max. switching voltage
277V AC
Max. switching current
5A
Min. switching capacity (reference value)*
1
100mA 5V DC
Electrical
characteristics
characteristics
Insulation resistance (Initial)
Min. 1,000M
(at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
(Initial)
Between open contacts
750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil)
10,000 V (initial)
Temperature rise
Max. 30
C
86
F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 5A, at 85
C
185
F
)
Operate time (at nominal voltage) (at 20
C
68
F
)
Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20
C
68
F
)
Max. 10 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
characteristics
Shock resistance
Functional
Min. 300 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
s.)
Destructive
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10
s.)
Destructive
10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical (at 180 cpm)
Min. 5
10
6
Electrical (at 20 cpm)
Min. 2
10
5
(5A 125V AC at rated load), Min. 10
5
(5A 250V AC at rated load)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40
C to +85C
–40
F to +185F
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed
(at nominal switching capacity)
(at nominal switching capacity)
20 times/min.
Unit weight
Approx. 4 g