TE Connectivity SR4M4024 PCB Mount Relay 24Vdc 8A 3 NO / 1 NC 4-1415053-1 Scheda Tecnica
Codici prodotto
4-1415053-1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
1
Safety Relay SR4 D/M
I
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
2 NO+2 NC or 3 NO+1 NC contacts
I
Forcibly guided contacts according to EN 50205
I
Rated current 8 A
I
Very small outlines
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0407
as per product date code 0407
Applications
Emergency shut-off, machine control, elevator and escalator
control, light barrier control
control, light barrier control
F0244-A
Approvals
V
REG.-Nr. 40005334,
Z
E214024,
T
968/EL 230.00/03
Technical data of approved types on request
Contact data
Contact configuration
3 N/O contacts and 1 N/C contact
or
2 N/O contacts and 2 N/C contacts
Contact set
single contact, forcibly guided
type A according to EN 50205
type A according to EN 50205
Type of interruption
micro disconnection
Rated current
8 A
Rated voltage / max.switching voltage AC
240/400 VAC
Maximum breaking capacity AC
2000 VA
Utilization class (AC-15) acc. IEC 60947-5-1
NO contact
I
e
3 A / U
e
250 VAC (inrush 30 A)
NC contact
I
e
1.5 A / U
e
250 VAC (inrush 15 A)
Contact material
AgSnO
2
Minimum contact load
10 mA / 5 V
Contact resistance
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
Mechanical endurance
10x10
6
cycles
Rated frequency of operation with / without load
6 min
-1
/ 150 min
-1
Coil data
Rated coil voltage range DC coil
5...110 VDC
Coil power DC coil
appr. 800 mW
Operative range
2
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.8
0.5
31+10%
806
006
6
4.5
0.6
45+10%
800
009
9
6.8
0.9
101+10%
802
012
12
9.0
1.2
180+10%
800
015
15
11.3
1.5
281+10%
801
018
18
13.5
1.8
405+10%
800
021
21
15.8
2.1
551+10%
800
024
24
18.0
2.4
720+10%
800
036
36
27.0
3.6
1620+10%
800
040
40
30.0
4.0
2000+10%
800
048
48
36.0
4.8
2880+10%
800
060
60
45.0
6.0
4500+10%
800
085
85
63.8
8.5
9031+10%
800
110
110
82.5
11.0
15125+10%
800
All figures are given for coil without preenergization, at ambient temperature +23°C