Emrol MultiPac - 30A Lead Acid Battery Charger Station, For 6, 12, 24V Batteries MULTIPAC Manuale Utente

Codici prodotto
MULTIPAC
Pagina di 6
INSTALLATION
3
When choosing a location for the charger, please note the
following:
Œ
The location must be dry, dust-free, and indoors. The acceptable
temperature range for operation is -20°C* to +40°C. A higher
ambient temperature will limit the current supply, see Appendix
A. CAUTION: The charger is not waterproof. Keep it dry and
away from areas of high humidity to avoid the risk of electrical
shock and damage to the charger. .

Ž
The equipment
may be installed
either vertically or
horizontally.
T o
e n s u r e
s u f f i c i e n t
ventilation, leave
approximately 10
c m
o f
s p a c e
around all sides of
the charger. Do
n o t
c o v e r
t h e
equipment.

The charging process generates explosive hydrogen gas.
Keep the area well ventilated. Never use an open flame or
equipment that produces sparks near the charger.
* The standard power cord may break if bent in temperatures below -5°C.
APPENDIXES
8
Appendix A. The effect of ambient temperature on output power
and fan speed.
-20
10
20
30
40
50
60
70
80
90
100
-10
0
2000
2500
3000
3500
4000
4500
5000
10
20
30
40
50
60
70
Output power/ %
Temperature
/ °C
Fan speed / rpm