MEAN WELL MDR-100-24 Scheda Tecnica
SPECIFICATION
MDR-100-12
MDR-100-24
MDR-100-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.6
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
12V
24V
48V
7.5A
4A
2A
0 ~ 7.5A
0 ~ 4A
0 ~ 2A
90W
96W
96W
120mVp-p
150mVp-p
24 ~ 30V
200mVp-p
48 ~ 56V
±1.0%
±1.0%
±1.0%
12 ~ 15V
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
50ms/230VAC 20ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
85%
86%
88%
1.3A/115VAC 0.8A/230VAC
COLD START 30A/115VAC 60A/230VAC
105 ~ 150% rated output power
Protection type :
Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
-10 ~ +60℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
346K hrs min. MIL-HDBK-217F (25℃)
℃
UL508, TUV EN60950-1 approved
96W Single Output Industrial DIN Rail Power Supply
M D R - 1 0 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■
55*90*100mm (W*H*D)
0.42Kg; 30pcs/13.6Kg/0.82CUFT
..
LEAKAGE CURRENT
<1mA / 240VAC
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
FUNCTION DC OK SIGNAL
Relay contact rating(max.): 30V/1A resistive
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
OVER TEMPERATURE
Shut down o/p voltage, auto-recovery or re-power on to recover
POWER FACTOR (Typ.)
PF≧0.95/230VAC PF≧0.98/115VAC at full load
EMC IMMUNITY
EMC EMISSION
File Name:MDR-100-SPEC 2013-11-26