Nkk Switches Toggle switch 250 Vac 10 A 2 x Off/On latch 1 pc(s) JWL21RAA/UC Scheda Tecnica

Codici prodotto
JWL21RAA/UC
Pagina di 9
Series JW
High Inrush 10 & 16 Amp Rockers
www.nkk.com
B40
Indicators
Accessories
Supplement
Tactiles
Keylocks
Rotaries
Pushbuttons
Illuminated PB
Slides
Programmable
B
Rockers
Touch
Tilt
 
Toggles
General 
Specifications
Electrical Capacity (Resistive Load)
 
Power Level:
  10A @ 125/250V AC for JWM & JWMW models; 10A @ 30V DC for JWMW;
 
  16A @ 125/250V AC for JWL & JWLW models; 5A @ 72V DC for telecommunication applications
Other Ratings
 
Contact Resistance:   10 milliohms maximum for JWM & JWMW; 20 milliohms maximum for JWL & JWLW
 
Insulation Resistance:  1,000 megohms minimum @ 500V DC
 
Dielectric Strength:  2,000V AC minimum between contacts for 1 minute minimum; 
 
  4,000V AC minimum between contacts & case for 1 minute minimum
 
Mechanical Life:  25,000 operations minimum 
 
Electrical Life:  25,000 operations minimum 
 
Nominal Operating Force:  JWM & JWMW Single Pole 3.92N & Double Pole 7.84N
 
  JWL Single Pole 5.00N & Double Pole 10.00N;   JWLW Double Pole 10.00N 
 
Angle of Throw:    26° 
Materials & Finishes
 
Rocker:  Polyphenylene ether (UL94V-0) 
Case/Base: 
Melamine (UL94V-0) 
 
Housing/Frame & Barrier:  Polyamide (UL94V-0) 
Contacts: 
Silver alloy with silver plating
  Interior Seal for JWM & JWL:  Polyphenylene sulfide (UL94V-0) 
Terminals: 
Brass with silver plating
Environmental Data
 Operating Temperature Range:  –25°C through +70°C (–13°F through +158°F) for JWM & JWL;
 
  –25°C through +85°C (–13°F through +185°F) for panel seal JWMW & JWLW models
 
Humidity:   90 ~ 95% humidity for 96 hours @ 40°C (104°F)
 
Vibration:  10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning  
 
  in 1 minute; 3 right angled directions for 2 hours
 
Shock:  50G (490m/s
2
) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
 
Sealing:  IP67 of IEC60529 standard for panel seal JWMW & JWLW models; dust resistant inner seal for others
Installation
 Soldering Time & Temperature:   Manual Soldering:  See Profile A in Supplement section. 
Standards & Certifications
 
Flammability Standards:  UL94V-0 for rocker, housing, seal & case/base of JWL, JWM,  JWMW & JWLW models
 
TV Ratings for UL & CSA:  JWM (TV-5) Overload Test  @ 120V AC for 50 operations:
 
   
Steady State Current (rms) 7.5A; Minimum Inrush Current  (peak) 111A.
 
  JWM (TV-5) Endurance Test  @ 120V AC for 25,000 operations:
 
   
Steady State Current (rms) 5A; Minimum Inrush Current  (peak) 78A.
 
  JWL (TV-8) Overload Test  @ 120V AC for 50 operations:
 
   
Steady State Current (rms) 12A; Minimum Inrush Current  (peak) 163A.
 
  JWL (TV-8) Endurance Test  @ 120V AC for 25,000 operations:
 
   
Steady State Current (rms) 8A; Minimum Inrush Current  (peak) 117A.
 
UL:  File No. E44145  
 
  JWM & JWMW models recognized at 10A @ 250V AC. 
 
  JWMW recognized at 10A @ 30V DC.
 
  JWL & JWLW models recognized at 16A @ 250V AC; JWL at 5A @ 72V DC.
 
  JWMW:  add “/U” to end of part number to order UL mark on switch;  add “/CUL”  to end of part 
 
  number to order cULus mark on switch.
 
  JWL:  add “/U-DC” to end of part number to request UL rating on DC rated switch.
 
CSA:  File No. 023535_0_000 
 
  JWM & JWMW models certified at 10A @ 250V AC;  JWL models certified at 16A @ 250V AC .
 
VDE:  License No. 115637 
 
  JWM models approved at steady state 5A, inrush 80A, resistive 10A, & motor load 6A all at  
  
  250V AC;  JWL models approved at steady state inrush 128A, resistive 16A, & motor load 8A  
 
  all at 250V AC.
 
  Note:  JWM & JWL Double Pole, Single Throw models approved only with the international  
 
  ON-OFF symbols on the actuator.