Panasonic ALFG2PF12 PCB Mount Relay ALFG2PF12 Scheda Tecnica

Codici prodotto
ALFG2PF12
Pagina di 6
LF-G (ALFG)
6
ds_61B12_en_lfg: 240913D
NOTES
 Usage, transport and storage 
conditions
1) Temperature: 
–40 to +60
C 
–40 to +140
F
 (When 
nominal coil voltage applied)
–40 to +85
C 
–40 to +185
F
 (When coil 
holding voltage is 45% to 80% of the 
nominal coil voltage)
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the 
temperature. Use within the range 
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for 
usage, transport, and storage
 –40 to +85C 
–40 to +185
F
 (When 45% to 
80%V of coil holding voltage)
4) Condensation
Condensation forms when there is a 
sudden change in temperature under 
high temperature and high humidity 
conditions. Condensation will cause 
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may 
freeze on the relay when the 
temperatures is lower than 0
C 
32
F
This causes problems such as sticking of 
movable parts or operational time lags.
6) Low temperature, low humidity 
environments
The plastic becomes brittle if the relay is 
exposed to a low temperature, low 
humidity environment for long periods of 
time.
 Solder and cleaning conditions
1) Please obey the following conditions 
when soldering automatically.
(1) Preheating: Within 120
C 
248
F
 
(solder surface terminal portion) and 
within 120 seconds
(2) Soldering iron: 260
C5C 
500
F41F
 (solder temperature) and 
within 6 seconds (soldering time)
2) Since this is not a sealed type relay, do 
not clean it as is. Also, be careful not to 
allow flux to overflow above the PC board 
or enter the inside of the relay.
 Certification
1) This relay is UL/C-UL certified.
UL/C-UL; 
Standard type (Contact Gap 1.5 mm 
.059 inch
 & 1.8 mm 
.071 inch
):
22A 277V AC General Use
High capacity type 
(Contact Gap 1.5 mm 
.059 inch
): 
31A 277V AC General Use
High capacity type 
(Contact Gap 1.8 mm 
.071 inch
): 
33A 277V AC General Use
2) This relay is certified by VDE 
(VDE0435).
VDE; 
Standard type (Contact Gap 1.5 mm 
.059 inch
 & 1.8 mm 
.071 inch
):
22A 250V AC cos
 = 0.8
High capacity type 
(Contact Gap 1.5 mm 
.059 inch
): 
31A 250V AC cos
 = 0.8
High capacity type 
(Contact Gap 1.8 mm 
.071 inch
): 
33A 250V AC cos
 = 0.8
 Cautions for use
1) For precautions regarding use and 
explanations of technical terminology, 
see Relay Technical Information.
2) To ensure good operation, please keep 
the voltage on the coil ends to 
5% (at 
20
C 
68
F
) of the rated coil operation 
voltage. Also, please be aware that the 
pick-up voltage and drop-out voltage may 
change depending on the temperature 
and conditions of use.
3) Keep the ripple rate of the nominal coil 
voltage below 5%.
4) Please test with actual device when 
using the coil holding voltage with PWM 
control.
5) The cycle lifetime is defined under the 
standard test condition specified in the 
JIS C5442 standard (temperature 15 to 
35
C 
59 to 95
F
, humidity 25 to 75%). 
Check this with the real device as it is 
affected by coil driving circuit, load type, 
activation frequency, activation phase, 
ambient conditions and other factors.
Also, be especially careful of loads such 
as those listed below.
(1) When used for AC load-operating and 
the operating phase is synchronous. 
Rocking and fusing can easily occur due 
to contact shifting.
(2) Highly frequent load-operating
When highly frequent opening and 
closing of the relay is performed with a 
load that causes arcs at the contacts, 
nitrogen and oxygen in the air is fused by 
the arc energy and HNO
3
 is formed. This 
can corrode metal materials.
Three countermeasures for these are 
listed here.
• Incorporate an arc-extinguishing circuit.
• Lower the operating frequency
• Lower the ambient humidity
6) This value can change due to the 
switching frequency, environmental 
conditions, and desired reliability level, 
therefore it is recommended to check this 
with the actual load.
7) Heat, smoke, and even a fire may 
occur if the relay is used in conditions 
outside of the allowable ranges for the 
coil ratings, contact ratings, operating 
cycle lifetime, and other specifications. 
Therefore, do not use the relay if these 
ratings are exceeded.
8) If the relay has been dropped, the 
appearance and characteristics should 
always be checked before use.
9) Incorrect wiring may cause 
unexpected events or the generation of 
heat or flames.
10) If complying with the Electrical 
Appliance and Material Safety Law (300V 
AC), please use with a nominal current 
no higher than 10A.
11) In order to reduce the occurrence of 
solder cracking due to thermal stress on 
the PC board, please use a double-face 
through hole PC board.
85
5
0
60
- 40
Humidity, %RH
Tolerance range
+32
+140
- 40
Temperature, 
°C
°F
(Avoid freezing 
when used at 
temperatures lower 
than 0
°C
(Avoid 
condensation 
when used at 
temperatures 
higher than 
0
°C
32
°F
)
32
°F
)
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation 
when used at 
temperatures 
higher than 
0°C
32°F
)
(Avoid freezing 
when used at 
temperatures 
lower than 
0°C
32°F
)
85
0
-40
+185
+32
-40
Temperature, °C
°F