Ningbo Forward N4100CHS3DC6C PCB Mount Relay NF42 001 A6W Scheda Tecnica

Codici prodotto
NF42 001 A6W
Pagina di 3
Ningbo Forward / Relay Catalog
1
1302
1302
NF42
· Small sizes 15.5 x 11 x 11.5mm
· High sensitivity 200mW
· Available with the two different terminal layouts
· UL/CUL approved
· Special design for alarm, security system, office
  equipement, medical equipment
· Comply with RoHS-Directive 2011/65/EU
Features
Type List
Terminal
style
Contact form
Designation (provided with)
Sealed type
washable
1C (SPDT)
Ordering Information
NF42    001    A    24   W
  1           2      3       4      5     
1. NF42
NF42A
-- Standard type
-- with different terminal Layou
2. 001
-- Single pole double throw - 1CO
3. A
-- Ag Au coated
4.
-- Coil voltage: 5=5V; 6=6V; 9=9V;
12=12V; 24=24V
5. Blank
W
-- Flux tight
-- Sealed washable
Contact Data
NF42 001 A .. W
Type of contact
Configuration
Rated load
Maximum switching current
Maximum switching voltage
Maximum switching capacity
Contact resistance
Contact material
90W / 625VA
1CO
3A/30VDC; 3A/125VAC
3A
60VDC / 220VAC
Single contact
50mΩ
Ag Au coated 
PCB Terminal
Coil rating (DC @+23°C)
Rated
voltage
(V)
Rated current
(mA) 
±10% 
Coil resistance
(Ω)
±10%
Max. continuous
voltage 
(V)
Pick up
voltage
Drop out
voltage
Power consump-
tion at rated 
voltage (mW)
5
6
9
12
24
40
125
33.3
22.2
16.6
8.3
180
405
720
2880
100 % of
rated
voltage
75 % of 
rated 
voltage
10 % of 
rated 
voltage
200
Flux tight
type
Terminal
Layout
Standard
Different
NF42 001 A .. 
NF42A 001 A .. 
NF42A 001 A .. W