5. Technical Data
Parameters
HY-WSC04-
12AWM
HY-WSC04-
24AWM
HY-WSC06-
24AWM
HY-WSC06-
48AWM
Rated
Battery
Voltage
12V 24V 24V 48V
Rated Wind Turbine Input Power 400W 400W 600W 600W
Maximum Wind Turbine Input Power
600W
600W
900W
900W
Rated Solar Input Power
150W
300W
300W
300W
Dumpload
Voltage
13.5V 27V 29V 58V
Charge Shutoff Voltage
14.5V
29V
Wind Turbine Brake Current
34A
17A
25A
13A
Battery Over Discharge Protection
Voltage
10.8V 21.6V 21.6V 43.2V
Battery Over Discharge Recovery Voltage
12V
24V
24V
48V
Output Over Voltage Protection Value
16V
32V
32V
64V
Light Control On Voltage (Factory Default ) 1V
【Adjustable】 2V【Adjustable】 2V【Adjustable】 4V【Adjustable】
Light Control Off Voltage (Factory Default) 1.5V
【Adjustable】 3V【Adjustable】 3V【Adjustable】 6V【Adjustable】
Rated Output Current of Load 1 and 2
10A
Load 1 Output Control Mode
(Factory Default)
3 Modes Selection
(
Light Control On and Light Control Off)
Load 2 Output Control Mode
(Factory Default)
3 Modes Selection
(
Light Control On and Time Control 5 Hours Off)
Dumpload Control Mode
PWM
Display Mode
LCD
Quiescent Current
≤20mA
Ambient Temperature & Humidity Range
-20
~
+55
°
C/35
~
85% RH ( No Consideration )
Dimension (L x W x H)
142×150×82mm
Net Weight
1.9kg
2 kg
In order to serve our customers better. Our company can adjust parameters configuration according to customer’s
requirement.
requirement.