Insys ISDN Terminal Adapter 4.0 11-02-01-02-00.015 Manuale Utente

Codici prodotto
11-02-01-02-00.015
Pagina di 60
Interface Types 
  11 
Version 2.02 – 01.04 
 
 
4.3  Interface Configuration Of The Basic Rate Interface 
4.3.1  Multipoint Connection (PTM, Point-To-Multipoint) 
 
For a multipoint connection, max. 8 ISDN terminal devices can be connected at the S0 
bus, two of which are usable at the same time. Each of the attached terminal devices 
can get its own call number (MSN) assigned. 
In this case the INSYS ISDN TA must be programmed to multipoint connection and the 
MSN must be configured. 
Programming INSYS ISDN TA 
 
 
AT**PTP
=0   
Multipoint connection (default) 
 
AT#z
=MSN   
(MSN = assigned call number, multiple subscriber number) 
 
AT&W
 
  Storing 
the 
setting