Functions 
21 
Version 2.02 – 01.04 
 
 
6  Functions 
6.1  Automatic Call 
Automatic call establishment is available in two modes: 
•  Initiation of an automatic call if DTR is on and 
•  automatic connection establishment irrespective of any status line. 
To enable an automatic call, the TA+ configuration parameter cmds has to be set to 6, 7 
or 8 (see table below). With setting this parameter, the baud rate will be set automati-
cally to 9.600 bit/s (br=4). 
An established connection will be indicated by a status line. (See also configuration 
commands cdcd and cdtr in the table). 
If a connection cannot be established successfully, an automatic redialing will be initi-
ated. The number of attempts as well as the pause duration until the next attempt are 
defined using the commands capa n and catry n
The dialed numbers are taken from the table catab.  
All entries of the table catab are used one after the other. 
cmds 6 
Automatic connection establishment if DTR is on. 
cmds 7 
Automatic connection establishment if the TA receives any data byte (autobauding is 
not supported, set br not equal to 0). 
cmds 8 
Automatic connection establishment irrespective of any status line. 
cato 
n 
Termination of an unsuccessful call after n seconds. n={3..255}, default: 15 seconds. 
capa 
n 
Call pause for n seconds before next call attempt. 
 
n = 0: no call attempt
.  n={0..255}, default: 3 seconds. 
catry 
n 
Automatic call: max. number of attempts for every number entry in catab. n={1..255}; 
default: 1 
catab
x nn/ss 
Sets entry number x to ISDNnumber nn and subaddress ss 
catab
x - 
Deletes entry number x 
catab
x 
Displays entry number x 
catab 
Displays all entries 
Maximum number of entries 
3; x = 1..3 
Maximum length of ISDN number 
20 digits 
Maximum length of subaddress 
20 digits 
Configuration with AT-Interface: 
Atxx