Insys ISDN Terminal Adapter 4.0 11-02-01-02-00.015 Manuale Utente
Codici prodotto
11-02-01-02-00.015
28
Operating Manual INSYS ISDN TA 4.0
Version 2.02 – 01.04
at&z3=0172
xxx
Target number of the mobile phone (without country code)
• Setting the network dependent parameters for recipients in the E-Plus network:
at*m3
network selection E-Plus
at&z1=01771167
Service center number of E-Plus
at&z3=49177
xxx
Target number of the mobile phone (the number starts
with the country code without “+”)
with the country code without “+”)
• Setting the MSN (own call number)
at**msn=
xxx
xxx stands for the call number
• Setting the baud rate
at%b
x
x stands for the selection of the respective baud rate, see
chapter: Overview about the most important basic com-
mands
chapter: Overview about the most important basic com-
mands
• Setting the SMS text
at*v
common text for both alarms (collective message)
at*v1
individual text for alarm 1
at*v2
individual text for alarm 2
-> NEW ALARMTEXT:
Enter the new text: max. 160 characters for collective mes-
sage if the individual texts are empty, otherwise 120 char-
acters for collective message and 40 characters for each in-
dividual text.
acters for collective message and 40 characters for each in-
dividual text.
• Storing the settings
at&w
• SMS dispatch by activating the alarm input or manually from the terminal program
at*x0
activation alarm 1
at*x1
activation alarm 2
6.3.2 Switch Output
The switch outputs OUT1 and OUT2 can be configured via AT commands (locally AT*Y,
remote ATS14, ATS15) or via TA+ configurator commands.
remote ATS14, ATS15) or via TA+ configurator commands.
Action Output
OUT1 Output
OUT2
Connect output to normally closed contact
AT*Y0,0
ATS14=0
ATS14=0
AT*Y1,0
ATS15=0
ATS15=0
Connect output to normally open contact
AT*Y0,1
ATS14=1
ATS14=1
AT*Y1,1
ATS15=1
ATS15=1
Output following DCD
AT*Y0,2
ATS14=2
ATS14=2
-
The state of the registers S14 and S15 can be stored with the command AT&W or the TA+
configuration command save.
configuration command save.