Command Overview 
  33 
Version 2.02 – 01.04 
 
 
7  Command Overview 
7.1  Overview About The Most Important AT Commands 
Default values are printed bold
Command Description 
A/ 
Repeat last command 
This command repeats the commands of the last entered command line. 
ATA 
Accept incoming call 
Using this command you can accept an incoming call, if automatic call accep-
tance is disabled (register S0 = 0). An incoming call is displayed by the message 
RING“ or the code “2“.
 
This command must be the last command in an AT command line. 
ATA[//<UUS1data>]
 
<UUS1data>
  data transmitted with UUS1 signaling 
ATB 
B channel protocol 
Transmission protocol for data communication in the B channel. 
ATB0
 
V.110 asynchronous (i.e. for BBS access) 
ATB1
 V.110 
synchronous 
ATB3
 
HDLC async to sync conversion (PPP asynchronous, single link 
PPP) (e.g. for Internet / dial-up network access) for internet / RAS 
network access)
 
ATB4
 
HDLC transparent (octets are packed into HDLC frames)
 
ATB5
 
Byte transparent (B channel data)
 
ATB10
 
X.75-NL (e.g. for BBS access)
 
ATB20
 
X.31 B channel (X.25 B channel, option)
 
ATB21
 
X.31 D channel (option)
 
 
AT%B 
Set local baud rate 
Sets the local baud rate of the INSYS ISDN TA to the desired value (fix value) or to 
auto detection. When auto detection is set, the INSYS ISDN-TA will recognize the 
required baud rate with every newly entered AT command by the terminal soft-
ware (PC). With all other settings the PC must use the same baud rate.
 
Must be the last command in an AT command line. 
AT%B0
 
Automatic baud rate detection enabled (autobauding)
 
AT%B1
 
Local baud rate     1.200 bit/s
 
AT%B2
 
Local baud rate     2.400 bit/s
 
AT%B3
 
Local baud rate     4.800 bit/s
 
AT%B4
 
Local baud rate     9.600 bit/s
 
AT%B5
 
Local baud rate   19.200 bit/s
 
AT%B6
 
Local baud rate   38.400 bit/s
 
AT%B7
 
Local baud rate   57.600 bit/s
 
AT%B8
 
Local baud rate 115.200 bit/s
 
AT%B9
 
Local baud rate 230.400 bit/s
 
 
Note:  If autobauding is selected (default) and after powering on the INSYS ISDN 
TA no AT command is entered, a response from INSYS ISDN TA (e.g. RING) 
will be sent with the baud rate 115.200 bit/s. 
ATCONF 