Command Overview 
  39 
Version 2.02 – 01.04 
 
 
Command Description 
The value will be changed by setting the B channel protocol (ATBx). 
AT**K 
Set Layer 2 window size 
Sets window size x layer 2 protocol B channel: 
x
 = 1 ..7, default: 7
 
AT**K
=x 
The default value is dependent of the selected B channel protocol. 
AT**PTP 
Set ISDN interface type 
AT**PTP
=0 
select point to multipoint mode (to connect ISDN terminals, 
default)
 
AT**PTP
=1 
select point to point mode (to connect ISDN switching systems) 
AT**RPWD 
Password for remote configuration 
Sets password for remote configuration to nn (1..32 chars) Default: no password.
 
AT**RPWD
=nn 
AT**SPID 
Set SPID (optional) 
For ISDN lines in the U.S. you have to set the SPID. You get it from your ISDN pro-
vider.
 
AT**SPID1
=xxxx Set 
SPID 
1
 
AT**SPID2
=xxxx Set 
SPID 
AT**<cmd
Execute configuration command 
Executes a configuration command. 
7.3  S Register 
The INSYS ISDN TA has status register which control the operation. 
S register can be read and written using the ATS command. Certain S registers can 
only be read, while others can only be set within a limited range of values.  
 
Register Description 
S0 
0: 
no automatic call acceptance, acceptance of an incoming call is con-
trolled by the data terminal (command ATA after RING) 
1: 
immediate call acceptance by the INSYS ISDN TA (default) 
2..n
call acceptance by the INSYS ISDN TA after "RING" messages
 
 
Note: 
The time between 2 ring messages can be set with the command “ring-
timer” (default = 5 s.) 
S1 
Ring tone counter (read only) 
S2 
Escape character (default = 43h) 
S3 
Return character (default = 0Dh) 
S4 
Line feed character (default = 0Ah) 
S5 
Backspace character (default = 1Ah) 
S7 
Waiting time for carrier signal in seconds (default = 30) 
S9 
Set PNP functionality for Windows95 (default=1, enabled)