Operating Manual INSYS ISDN TA 4.0
Version 2.02 – 01.04
No circuit/channel available
No B channel is available for a call at the moment. The ISDN TA triggers a locking release
upon this and makes a B channel available.
ISDN network out of order
upon this and makes a B channel available.
ISDN network out of order
Problems in the ISDN network. Wait some time and try again to call.
Temporarily failure
Temporarily failure
Temporary problems in the ISDN network. You can immediately try to call again.
Incompatible destination
Incompatible destination
The terminal device of the remote side is not compatible with the calling terminal device.
The call cannot be accepted therefore. This failure occurs e.g. if the remote terminal de-
vice is a regular phone.
The call cannot be accepted therefore. This failure occurs e.g. if the remote terminal de-
vice is a regular phone.
9.4 Extended Error Messages For ISDN
Reason
(hexadecimal)
(hexadecimal)
Description AT
response
X.25 re-
sponse
sponse
0000
No error
0001
NCPI ignored
0002
Flags ignored
0003
Alert already sent
1001
Too much CAPI applications
1002
Logic block size too small
1003
Buffer bigger than 64k
1004
Buffer of the message too small
1005
Too much logical connections
1006
Reserved 1
1007
Message has not been accepted
1008
Register: OS resources failure
100a
External equipment not supported
100b
Only external equipment
1101
Wrong application ID
1102
Invalid command or message length
1103
Message queue full
1104
Message queue empty