Functions 
INSYS Modem 336/56k 4.1 (UL) 
5.12  Data Transmit Controller (Idle Connection Control) 
 
Not for INSYS Modem LL. 
The Data Transmit Control (DTC) is a function integrated in 
the firmware which monitors the data transmission in 
online mode. This function prevents the modem to stay 
online for an unlimited amount of time, although no data is 
being transmitted anymore. 
5.12.1  Activation 
The activation takes place in the registry S15, and any time 
period between 1 and 255 seconds may be set.  
ATS15=<n>
 
5.12.2  Mode of Operation for the “Timer” 
The timer will run immediately after the modem goes off-
hook. After the set time has been reached, a RESET is per-
formed.  
The timer is reset by each byte that is sent via the serial in-
terface. 
Note: 
The timer will run immediately after the mo-
dem goes off-hook. We therefore strongly rec-
ommend to not setting any times below 30 sec-
onds.
 
In remote mode, idle connection control at the 
modem must be deactivated to prevent the 
connection from being interrupted after the 
timer has run out. 
 
The remote data transmission will not reset the 
timer.
 