Insys Modem 56k 4.1 11-02-01-01-40.028 Manuale Utente

Codici prodotto
11-02-01-01-40.028
Pagina di 100
INSYS Modem 336/56k 4.1 (UL) 
Technical Data 
13.7  Reset 
A reset is possible via the screw terminal marked Reset, using an external device. 
A low potential must be applied at the terminal for at least 3 seconds. 
Alternatively, the reset key should be pressed at least 3 seconds to trigger a reset. 
13.8  Digital Inputs and Outputs 
13.8.1  Alarm input 
LOW  0 .. 1  V 
HIGH  4 .. 12  V 
Input current from LOW to internal +5V: Type 0.5 mA 
 
13.8.2  Switch output 
Potential-free relay switches  
maximum switch voltage: 
30  V (DC) 
/ 42  V (AC) 
maximum current load: 
1  A (DC) 
/ 0.5  A (AC) 
13.9  Certifications 
The INSYS Modem336/56k 4.1 (UL) bears the CE symbol of conformity. This sym-
bol indicates that on account of its design and implementation, the INSYS Mo-
dems 336 4.1 or the INSYS Modem 56k 4. are in compliance with the currently 
valid versions of the following EC directives: 
Conformity:  A conformity declaration regarding CE for your device may be ob-
¾ 
89/336/EEC (EMC directive) 
¾ 
73/23/EEC   (Low voltage directive) 
¾ 
91/263/EEC (Telecommunications devices directive) 
Approvals: 
¾ 
R&TTE 
¾ 
CTR 21 (Europe) 
¾ 
CE 
Applies only to INSYS Modem 56k 4.1 UL: 
¾ 
UL certification 
July 06 
95