4.2.3  Remote configuration 
During a data connection, you can put the INSYS GSM into remote configuration mode 
via the data connection by entering the escape sequence at the remote terminal.  
Requirements: 
 
The data communication is perhaps active. 
 
There has been no data traffic for at least one second. 
Entering the escape sequence: 
1. 
Swiftly enter the characters *** (without <CR>). 
2. 
Wait at least one second. 
 
The device is in command mode. 
The data connection remains established, while the entered extended INSYS AT** 
commands are processed at the remote INSYS GSM. The INSYS GSM changes back to 
connection mode with AT**EXIT.  
If it has been set, the remote configuration password is queried before changing to the 
remote configuration mode. 
4.2.4  SMS configuration  
You can also send the extended INSYS AT** commands to the INSYS GSM via SMS. (see 
Chap. 6.2.4) 
The commands sent via SMS will be executed as soon as the INSYS GSM is in command 
mode. 
4.3 
Alarm State 
As soon as an alarm input of the INSYS GSM has been activated, existing data and voice 
connections are terminated. Incoming commands are ignored during the processing of 
the alarm actions. If an input is activated while processing an alarm at the other input, 
the second alarm state is saved and executed subsequently. 
If an connection cannot be established, a re-dial is attempted after one minute until the 
defined maximum number of dial-up attempts is reached. (see Chap. 6.1.3) 
The LED Status is flashing during the (attempted) connection set-up.