Insys GSM 4.2 Compact 11-02-01-03-04.002 Manuale Utente

Codici prodotto
11-02-01-03-04.002
Pagina di 89
Functions and their Configuration 
 
INSYS GSM 4.2  
INSYS GSM 4.2 compact 
 
70
 
 
 
 
 
 
 
 
 
 
 
 
Sep-06
 
6.4 
Switch Outputs 
The INSYS GSM has two potential-free relay switches (see Chap.2.5.7 ), which can be 
switched through a command or the status of the device.  
You configure both switch outputs independently from each other.  
You have the following options for switching the switch outputs: 
¾
  AT command  
¾
  SMS command (see Chap. 6.2.4) 
¾
  DTMF query (see Chap. 6.1.2) 
SMS command  
The automatic processing of SMS messages has to be enabled. (see Chap. 6.2.3) 
DTMF command  
The automatic processing of DTMF tones has to be enabled. (see Chap. 6.1.2) 
Additional options 
The following additional options are available: 
¾
  Activate by waiting alarm at relevant alarm input 
The INSYS GSM can signal to an external device that the alarm input is busy. 
¾
  Activate for the duration of an incoming RING signal 
An incoming RING signal switches the switch output active. With this, an external 
signal (lamp, horn) can be switched, for example. 
¾
  Activate on radio network loss 
The INSYS GSM switches the switch output if the GSM radio network fails. 
 
 
 
Note 
The following conditions must be complied with for switching on 
radio network loss. 
¾
  AT**GSMREQ=1 
¾
  The serial interface is inactive.  
The failure may last up to 60 seconds until the INSYS GSM switches 
the switch output. 
Procedure: Configure the switch outputs with HSComm 
1. 
Switch to the tab "Alarm/Switch1" or "Alarm/Switch2". 
2. 
Activate the requested activation type for the switch output in the group "Switch 
output1" or "Switch output2".