Emmerich ready to use 1.2 V AA ZLF 255065 Scheda Tecnica

Codici prodotto
255065
Pagina di 7
4. Performance Testing  
4.1. TEST CONDITIONS 
  4.1.1  The battery to be tested is the product within one month after being received by customer.  
4.1.2 Ambient conditions: 
                   Temperature                                +20 ±5
 
                    Humidity                                     +65%±20% 
4.2 Testing Tools  
4.2.1 Voltage meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V. 
4.2.2 Current meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than 
0.01Ω/V(including wires). 
4-2.3. Micrometer caliper:  
With precision of 0.02mm. 
4-2.4. Internal impedance meter:  
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4. 
4-2.5: Impedance loaded meter:  
Value of impedance is with +5% error allowed (including external wires). 
 4.2.6 Incubators   Accuracy ±2℃ 
 
4.3 Test methods and benchmarks  
Item Test 
Method Benchmark 
1.Appearance: 
—  eyeballing 
—  batteries shall be free from 
any stains; scratches or 
deformations, which may 
reduce the commercial value 
when visually inspected 
2.Size: 
—  caliper measurement。 
—  The size shall comply with the 
specified size as the attached 
drawing  
3.Insulate 
impedance 
—  measured with a Megger overpack 
and battery electrode between the 
degree of insulation。 
—  outer sleeve shall exceed    10  
MΩ。 
4.Weight 
—  using disk-scale measurement。 
—  approximate   12.0 g。 
5.Charge 
Voltage 
—  Following a period of discharge at 
0.2CmA down to a terminal voltage 
of 1.0V, standard charge, the cell or 
battery shall be checked at 5 minutes 
before finish charging。 
—  The voltage shall be less than    
1.6  V。 
6.Open circuit 
voltage: (O.C.V.) 
—  Following a standard charge period, 
the open circuit voltage of the cell or 
battery shall be checked within 1 
hour.。 
—  The O.C.V. shall exceed 1.25  
V per cell.。                     
7.Closed 
circuit voltage:  
—  Following a standard charge period, 
the closed circuit voltage of the cell 
—  The C.C.V. shall exceed    1.2  
V per cell 。 