Cypress Semiconductor CY3280-MBR3 Scheda Tecnica

Pagina di 17
CY8CMBR3002, CY8CMBR3102
CY8CMBR3106S, CY8CMBR3108
CY8CMBR3110, CY8CMBR3116 Datasheet
Document Number: 001-85330 Rev. *G 
Page 14 of 37
Figure 5.  CSx Controls GPOx with LED ON Time Enabled
Can be enabled only when the GPO is directly controlled by a 
CapSense sensor
Can be enabled or disabled on each sensor and the ON Time 
duration can be configured from 0 to 2 seconds in 20-ms incre-
ments
Can be enabled in all configurations of GPOs except the Toggle 
mode
Not applicable when the sensor status is turned off by Sensor 
Auto Reset
Toggle
The controller can toggle the GPO state at every rising edge 
of a sensor activation event to mimic the functionality of a 
mechanical toggle switch (a touch event for a button sensor 
and a proximity event for proximity sensors activates a sensor).
Figure 6.  CSx Controls GPOx with the Toggle Enabled
Can be enabled only when the GPO is directly controlled by a 
capacitive sensor.
Can be enabled or disabled individually on each capacitive 
sensor.
Can be enabled in all configurations of GPOs—that is, Active 
LOW and Active HIGH DC output, PWM output, open-drain, 
and strong drive modes. 
Buzzer Signal Output
Produces a PWM signal to drive a Piezo-Buzzer that generates 
audio feedback when a touch is detected on a CapSense button 
or a guard sensor.
Supports buzzer connection, as shown in the following figure.
Figure 7.  Buzzer Connection
PWM frequency is configurable: The buzzer frequency is 
configurable to meet different Piezo-Buzzer drive requirements 
and to provide different tones. The buzzer frequency may be 
configured either by using th
corresponding control register. Refer to 
 for the supported buzzer frequencies.
Generates PWM output for a fixed duration (ON time) when a 
touch is detected. The ON time is configurable through 
, from 100 ms to 12.7 s, in steps of 100 ms,
Buzzer signal output and EMC (refer to the 
) are mutually exclusive features. These must 
not be enabled simultaneously.
Figure 8.  Buzzer Activation on a Touch Event
The buzzer output does not restart if multiple trigger events occur 
before the Buzzer ON Time elapses.
CSx bit in 
BUTTON_STAT
GPOx
LED ON Time
BUTTON_STAT 
register shows 
sensor inactivation
CSx physical 
status
Sensor 
Deactivated
Button response time
Sensor 
Activated
CSx
GPOx
Sensor 
Activated
Sensor 
Deactivated
Sensor 
Activated
CY8CMBR3xxx
BUZ
Buzzer
V
DDIO
Note
4. Buzzer must be connected between V
DDIO
 and the BUZ pin. If V
DDIO
 is not available on the device, connect the buzzer to V
DD
 instead of V
DDIO
.
CSx
BUZ
Buzzer ON Time
CSx Active
Sensor 
Activated