Texas Instruments BQ24071 Evaluation Module BQ24064EVM-005 BQ24064EVM-005 Scheda Tecnica

Codici prodotto
BQ24064EVM-005
Pagina di 10
www.ti.com
Test Summary
dash numbers).
3. Verify that the green LED (D3) is lit for -001/2/5/6/7.
4. Verify that the voltage on J2-2 (TS, CE, TE) to J2-1 (BAT-) is between 2 VDC to 3 VDC for -001/3/5/6,
between 0 VDC to 0.4 VDC for -002/7, and between 4.6 VDC to 5.6 VDC for -004.
5. Verify the voltage between J6-2 (CE)and J1-2 (DC-) for -003/4. Jumper should not be shorting J6 pins.
6. Open switch SW2, and then close it.
7. Verify that the output voltage, BAT+, settles between 3.2 V to 3.95 V.
8. Verify that the input current is between 0.69 A to 0.75 A.
9. Open switch SW3.
10. Verify that the input current is between 100 mA and 150 mA.
11. Verify that the output voltage, BAT+, is between 4.150 VDC and 4.250 VDC.
12. Open switch SW2.
13. With a scope (250 ms/div, 1 V/div), verify that output, BAT+, charges and discharges between the
maximum limits of 3 V and 4.7 V, with a period of between 600 ms to 850 ms.
14. Verify that the LEDs flash between red (D1) and green (D2, mostly on green).
15. Remove J7 and verify that voltage on BAT+ is between 4.150 VDC and 4.250 VDC, and the red LED
(D1) turns on.
16. Install J7.
17. Open SW4, and verify that D1 and D2 are off and D3 is on (D3 does not apply to -003/4).
18. With a scope on BAT+, verify that a square wave is seen between the maximum limits of 1.3 VDC
and 4.35 VDC and between 3.5 Hz and 4.5 Hz.
19. Close switches SW2, SW3, and SW4 (all switches should be closed now), and power down the
supply.
bq2406x Evaluation Module
4
SLUU235 – February 2006