Texas Instruments EVM430-F6736 - MSP430F6736 EVM for Metering EVM430-F6736 EVM430-F6736 Scheda Tecnica

Codici prodotto
EVM430-F6736
Pagina di 124
SDA
SCL
t
HD,DAT
t
SU,DAT
t
HD,STA
t
HIGH
t
LOW
t
BUF
t
HD,STA
t
SU,STA
t
SP
t
SU,STO
MSP430F673x
MSP430F672x
SLAS731C – DECEMBER 2011 – REVISED FEBRUARY 2013
eUSCI (I2C Mode)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see
)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
Internal: SMCLK, ACLK
f
eUSCI
eUSCI input clock frequency
External: UCLK
f
SYSTEM
MHz
Duty cycle = 50% ± 10%
f
SCL
SCL clock frequency
2 V/3 V
0
400
kHz
f
SCL
= 100 kHz
5.1
t
HD,STA
Hold time (repeated) START
2 V/3 V
µs
f
SCL
> 100 kHz
1.5
f
SCL
= 100 kHz
5.1
t
SU,STA
Setup time for a repeated START
2 V/3 V
µs
f
SCL
> 100 kHz
1.4
t
HD,DAT
Data hold time
2 V/3 V
0.4
µs
f
SCL
= 100 kHz
2 V/3 V
5.0
t
SU,DAT
Data setup time
µs
f
SCL
> 100 kHz
2 V/3 V
1.3
f
SCL
= 100 kHz
5.2
t
SU,STO
Setup time for STOP
2 V/3 V
µs
f
SCL
> 100 kHz
1.7
UCGLITx = 0
75
220
ns
UCGLITx = 1
35
120
ns
Pulse duration of spikes suppressed by input
t
SP
2 V/3 V
filter
UCGLITx = 2
30
60
ns
UCGLITx = 3
20
35
ns
UCCLTOx = 1
30
ms
t
TIMEOUT
Clock low timeout
UCCLTOx = 2
2 V/3 V
33
ms
UCCLTOx = 3
37
ms
Figure 17. I2C Mode Timing
LCD_C - Recommended Operating Conditions
PARAMETER
CONDITIONS
MIN
NOM
MAX
UNIT
Supply voltage range, charge
LCDCPEN = 1, 0000 < VLCDx
1111
V
CC,LCD_C,CP en,3.6
2.2
3.6
V
pump enabled, V
LCD
3.6 V
(charge pump enabled, V
LCD
3.6 V)
Supply voltage range, charge
LCDCPEN = 1, 0000 < VLCDx
1100
V
CC,LCD_C,CP en,3.3
2.0
3.6
V
pump enabled, V
LCD
3.3 V
(charge pump enabled, V
LCD
3.3 V)
Supply voltage range, internal
V
CC,LCD_C,int. bias
LCDCPEN = 0, VLCDEXT = 0
2.4
3.6
V
biasing, charge pump disabled
Supply voltage range, external
V
CC,LCD_C,ext. bias
LCDCPEN = 0, VLCDEXT = 0
2.4
3.6
V
biasing, charge pump disabled
Supply voltage range, external
V
CC,LCD_C,VLCDEXT
LCD voltage, internal or external
LCDCPEN = 0, VLCDEXT = 1
2.0
3.6
V
biasing, charge pump disabled
External LCD voltage at
V
LCDCAP/R33
LCDCAP/R33, internal or external
LCDCPEN = 0, VLCDEXT = 1
2.4
3.6
V
biasing, charge pump disabled
Copyright © 2011–2013, Texas Instruments Incorporated
69