Texas Instruments TPS53126 Dual Synchronous Step-Down Controller Evaluation Module TPS53126EVM-600 TPS53126EVM-600 Scheda Tecnica

Codici prodotto
TPS53126EVM-600
Pagina di 20
Test Setup
www.ti.com
5.1.4
Oscilloscope and Probe
The oscilloscope, analog or digital, must be set for ac-coupled measurement with 20-MHz bandwidth
limiting. Use 20-mV/division vertical resolution, 1-µs/division horizontal resolution for output ripple voltage
test.
Oscilloscope probes with exposed conductive ground barrels are recommended.
5.1.5
Recommended Wire Gauge
VIN to J3 – The connection between the source voltage V
IN
and J1 of TPS53126EVM-600 can carry as
much as 2 Adc. The minimum recommended wire size is AWG 16 with the total length of wire less than 2
feet (1-foot input, 1-foot return).
J1 to LOAD1 and J2 to LOAD2 – The connection between J1 and LOAD1, and J2 and LOAD2 of
TPS53126EVM-600 can carry as much as 4 Adc each. The minimum recommended wire size is AWG 14
with the total length of wire less than 2 feet (1-foot input, 1-foot return).
5.1.6
Other Test Equipment
FAN – The TPS53126EVM-600 evaluation module includes components that can get hot to touch.
Because this EVM is not enclosed to allow probing of circuit nodes, a small fan capable of 200-400 lfm is
recommended to reduce component temperatures when operating.
5.2
Recommended Setup
shows the recommended test setup to evaluate the TPS53126EVM-600. Working at an ESD
workstation, ensure that any wrist straps, bootstraps, or mats are connected referencing the user to earth
ground before power is applied to the EVM. An electrostatic smock and safety glasses also are
recommended.
8
TPS53126EVM-600
SLVU435 – February 2011
© 2011, Texas Instruments Incorporated