Texas Instruments SN65HVS885EVM Evaluation Module SN65HVS885EVM SN65HVS885EVM Scheda Tecnica

Codici prodotto
SN65HVS885EVM
Pagina di 3
1
EVM Schematic and Layout
User's Guide
SLAU275 – January 2009
SN65HVS885EVM
The SN65HVS885EVM evaluation module (EVM) supports the rapid, parametric evaluation of the
SN65HVS885 digital input serializer. It is intended to be used in conjunction with the SN65HVS885 data
sheet, (SLASxxx). Note this EVM is not intended for electromagnetic compatibility (EMC) tests.
shows the board circuit schematic and
shows the board layout top view. The board
includes a terminal block, TB1, and three connectors, JMP1 to 3.
TB1 receives the board supply of 5 V nominal. VCC supplies the SN65HVS885 device and VIN provides
the supply for sensor switches.
Upon the application of VCC the red VCC LED indicates 5V availability to the device.
JMP1 provides the field inputs IN0:IN7 for field voltages of 24 V nominal. They can be applied via:
a. an external supply in series to a sensor switch connected to a field input,
b. or a sensor switch connected between and input and VIN,
c. or a direct connection between an input and VIN.
In all three cases, a 24-V level represents the ON-status of a sensor switch, which is indicated by the
corresponding LEDs D0:D7.
JMP2 provides access to the control and data lines of the internal serializer. To operate the serializer CE
must be connected either to ground or to CLK.
Upon an active-low load pulse, (a high-to-low-to-high transition) at LD, the status information of the field
inputs is latched into the serializer. Applying eight consecutive clock cycles at CLK, shifts out the serializer
data at SOP with each rising edge of the clock.
Cascading of multiple boards is also possible by connecting the SOP output of a leading device with the
SIP input of a following device.
JMP3 allows the selection of three different debounce times and 3 different current limits.
Debounce default is 3-ms and does not require any connection between the DB inputs to ground.
Otherwise for zero debounce time connect DB1 to ground, and for 1-ms debounce time connect DB0 to
ground.
Note, that open DB inputs are internally pulled high and will not float.
Setting a specific current limit requires a connection between the R
LIM
output and one of the resistors,
RLIM 1:3. For a current limit of 3.6 mA connect R
LIM
to R8, for 3 mA to R9, and for 2.5 mA to R10.
For detailed information on device functionality and system design recommendations refer to the
SN65HVS885 datasheet.
SLAU275 – January 2009
SN65HVS885EVM
1