Test Procedure
6
Test Procedure
Set up the EVM per
.
CAUTION
High voltage and high temperature present when the EVM is in operation!
High voltage present for some time after power down of the EVM. Check output
terminals with a voltmeter before handling the EVM!
6.1
Power Factor and Efficiency Measurement Procedure
1. Check the switch S1 at ON position. If S1 is not at ON position, switch S1 to the position ON.
2. Turn on the ventilation fan and keep the fan in operation during the time of test.
3. Set the AC source voltage to 115 V
AC
and frequency to 60 Hz. But keep the AC source powered off
4. Prior to connecting the AC source, set the current to 2.5-A peak and 2.5-A limit. Connecting AC source
to LINE and NEUTRAL terminals as shown in
.
5. Connect voltmeter V1 across the J3 as shown in
6. Connect ammeter A1 to J3 positive terminal and connect ammeter A1 to Load-1. Then connect Load-1
negative terminal to J3 negative terminal.
7. Connect 10-V Bias to J1, turn on 10-V Bias.
8. Set Load-1 to constant current mode to sink 0.2 A
DC
and set Load-1 at 100 V
DC
input range before
turning on the AC source.
9. Turn on the AC source.
10. Varying the load current from 0.2 A to 1.2 A, along with the load current variation:
(a) Read input voltage, input real power, and power factor from the AC source.
(b) Read output voltage and output current from V1 and A1.
11. Turn off the AC source.
12. Set the AC source voltage to 230 V
AC
and frequency to 50 Hz.
13. Repeat step 8 and 10.
NOTE:
Start up is normally with load current not greater than 0.2A.
Start up with no load, or less than 0.2-A load, may make output voltage higher and can be as
high as 88 V.
Start up with load current greater than 0.2 A may trigger over current protection and may
make output voltage in hiccup operation.
Load step down to zero may make output voltage higher and can be as high as 90 V.
6.2
Equipment Shutdown
1. Shut down the AC source
2. Shut down the 10-V Bias
3. Shut down the load
4. Shut down the FAN
CAUTION
High voltage may present after power down of the EVM for some time. Check
output terminals with a voltmeter before handling the EVM!