Extreme networks BlackDiamond 8810 10-Slot Chassis 41011 Scheda Tecnica
Codici prodotto
41011
Extreme Networks Data Sheet
© 2010 Extreme Networks, Inc. All rights reserved.
BlackDiamond 8800 Series—Page 2
High Availability
Redundant System Design
Redundant Management Modules
The BlackDiamond 8800 series of
modular switches are configured with an
automatic failover mechanism so that if
one Management Switch Module (MSM)
fails, the second MSM will automatically
take over management responsibility for
the entire switch. This feature is critical
for networks running voice and other
mission-critical applications. This
capability is not available for the
BlackDiamond 8500-series modules.
modular switches are configured with an
automatic failover mechanism so that if
one Management Switch Module (MSM)
fails, the second MSM will automatically
take over management responsibility for
the entire switch. This feature is critical
for networks running voice and other
mission-critical applications. This
capability is not available for the
BlackDiamond 8500-series modules.
Advanced Chassis Design
for Availability
BlackDiamond 8800 series switches
include a passive backplane complement-
ed by high availability design elements
such as isolated control and data planes,
redundant controller boards for power
distribution, and fan control and environ-
mental monitoring to identify anomalies
before they affect network availability.
include a passive backplane complement-
ed by high availability design elements
such as isolated control and data planes,
redundant controller boards for power
distribution, and fan control and environ-
mental monitoring to identify anomalies
before they affect network availability.
Redundant Load Sharing
Power Supplies
BlackDiamond 8800 series switches
support a set of redundant power
configurations that can load share up to
six internal power supplies simultaneous-
ly. Three power supplies in a 2 + 1
redundancy configuration can power a fully
loaded chassis with gigabit or 10 Gigabit
Ethernet ports. In addition, without the
need of an external power tray, three
power supplies are available to support
large PoE implementations.
support a set of redundant power
configurations that can load share up to
six internal power supplies simultaneous-
ly. Three power supplies in a 2 + 1
redundancy configuration can power a fully
loaded chassis with gigabit or 10 Gigabit
Ethernet ports. In addition, without the
need of an external power tray, three
power supplies are available to support
large PoE implementations.
Redundant Cooling Fans in a
Hot-Swappable Fan Tray
Redundant cooling is delivered by a tray
of nine fans (BlackDiamond 8810) or six
fans (BlackDiamond 8806). The fan tray
itself is hot swappable so the
BlackDiamond 8800 series switches keep
operating while the fan tray is replaced.
of nine fans (BlackDiamond 8810) or six
fans (BlackDiamond 8806). The fan tray
itself is hot swappable so the
BlackDiamond 8800 series switches keep
operating while the fan tray is replaced.
Modular Operating System for
Non-Stop Operations
Non-Stop Operations
True Preemptive Multitasking
and Protected Memory
BlackDiamond 8800 series switches allow
each of the many protocols such as Open
Shortest Path First (OSPF) and Spanning
Tree to run as separate OS processes that
each of the many protocols such as Open
Shortest Path First (OSPF) and Spanning
Tree to run as separate OS processes that
are protected from each other. This
drives increased system integrity and
inherently protects against Denial of
Service (DoS) attacks.
drives increased system integrity and
inherently protects against Denial of
Service (DoS) attacks.
Process Monitoring and Restart
ExtremeXOS dramatically increases
network availability using process
monitoring and restart. Each indepen-
dent OS process is monitored in real time.
If a process becomes unresponsive or
stops running, it can be automatically
restarted.
network availability using process
monitoring and restart. Each indepen-
dent OS process is monitored in real time.
If a process becomes unresponsive or
stops running, it can be automatically
restarted.
Loadable Software Modules
The modular design of ExtremeXOS
allows the upgrading of individual
software modules, should this be
necessary, leading to higher availability in
the network (see Figure 1).
allows the upgrading of individual
software modules, should this be
necessary, leading to higher availability in
the network (see Figure 1).
High Availability Network
Protocols
Protocols
Ethernet Automatic Protection
Switching (EAPS)
EAPS allows the IP network to provide
the level of resiliency and uptime that
users expect from their traditional voice
networks. EAPS is superior to the
Spanning Tree or Rapid Spanning Tree
Protocols, offering sub-second (less than
50 milliseconds) recovery and delivering
consistent failover regardless of number
of VLANs, number of network nodes or
network topology. In most situations,
VoIP calls do not drop and digital video
feeds do not freeze or pixelize because
the level of resiliency and uptime that
users expect from their traditional voice
networks. EAPS is superior to the
Spanning Tree or Rapid Spanning Tree
Protocols, offering sub-second (less than
50 milliseconds) recovery and delivering
consistent failover regardless of number
of VLANs, number of network nodes or
network topology. In most situations,
VoIP calls do not drop and digital video
feeds do not freeze or pixelize because
EAPS allows the network to recover
almost transparently from link failure.
almost transparently from link failure.
Spanning Tree/Rapid Spanning
Tree Protocols
BlackDiamond 8800 series switches
support Spanning Tree (802.1D), Per
VLAN Spanning Tree (PVST+), Rapid
Spanning Tree (802.1w) and Multiple
Instances of Spanning Tree (802.1s)
protocols for Layer 2 resiliency.
support Spanning Tree (802.1D), Per
VLAN Spanning Tree (PVST+), Rapid
Spanning Tree (802.1w) and Multiple
Instances of Spanning Tree (802.1s)
protocols for Layer 2 resiliency.
Software Enhanced Availability
Software enhanced availability allows
users to remain connected to the network
even if part of the network infrastructure
is down. BlackDiamond 8800 series
switches constantly check for problems in
the uplink connections using advanced
Layer 3 protocols such as OSPF, VRRP
and Extreme Standby Router Protocol™
(ESRP) (ESRP supported in Layer 2 or
Layer 3), and dynamically route around
the problem.
users to remain connected to the network
even if part of the network infrastructure
is down. BlackDiamond 8800 series
switches constantly check for problems in
the uplink connections using advanced
Layer 3 protocols such as OSPF, VRRP
and Extreme Standby Router Protocol™
(ESRP) (ESRP supported in Layer 2 or
Layer 3), and dynamically route around
the problem.
Equal Cost Multipath
Equal Cost Multipath enables uplinks to
be load balanced for performance and cost
savings while also supporting redundant
failover. If an uplink fails, traffic is
automatically routed to the remaining
uplinks and connectivity is maintained.
be load balanced for performance and cost
savings while also supporting redundant
failover. If an uplink fails, traffic is
automatically routed to the remaining
uplinks and connectivity is maintained.
Link Aggregation (802.3ad)
Cross-module link aggregation enables
trunking of up to eight links on a single
logical connection, for up to 80 Gbps of
redundant bandwidth per logical connection.
trunking of up to eight links on a single
logical connection, for up to 80 Gbps of
redundant bandwidth per logical connection.
A high-performance network connection, whether used to connect PCs and IP telephones at the access layer or to
interconnect servers in a cluster, is only useful if it is also highly available. BlackDiamond 8800 series modular switching
family incorporates extensive hardware redundancy and a modular OS—ExtremeXOS—that provides the network recovery
required by converged applications.
interconnect servers in a cluster, is only useful if it is also highly available. BlackDiamond 8800 series modular switching
family incorporates extensive hardware redundancy and a modular OS—ExtremeXOS—that provides the network recovery
required by converged applications.
5027-02
• Processes are monitored
and can be restarted or
other action taken if
necessary
• Hitless failover
infrastructure for dual
management systems
and stacking
BGP
OSPF
SSH-2
V1.3.1
SSH-2
V1.3.2
Third
Party
Application
ExtremeXOS
Kernel
Kernel Loadable
Module
Memory protected
processes under
real-time scheduling
that cannot impact
each other nor kernel
1
Designed to allow
application modules to
be upgraded during
runtime
3
Application modules
can be added during
runtime
2
Figure 1: ExtremeXOS Modular Design