Energizer ENCR1220 611321 Scheda Tecnica

Codici prodotto
611321
Pagina di 1
Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation:
ANSI-5012LC, IEC-CR1220
Nominal Voltage:
3.0 Volts
Typical Capacity:
40 mAh (to 2.0 volts)
(Rated at 45K ohms at 21°C)
Typical Weight:
0.78 grams (0.03 oz.)
Typical Volume:
0.25 cubic centimeters (0.02 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
153 milliwatt hr/g, 464 milliwatt hr/cc
Typical Li Content:
0.006 grams (0.0002 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Safety - lithium coin batteries lodged in the esophagus should be removed
immediately.  Leakage, chemical burns and potential perforation can
occur within hours of ingestion.  Seek medical attention immediately.  Have
physician call the NATIONAL BATTERY INGESTION HOTLINE for advice
and follow-up (202)-625-3333) collect day or night. 
Load
Cutoff
2.0V
(ohms)
(hours)
45,000
628
Bkgnd Drain: Continuous
62K ohms
0.046 mA @2.85V
Pulse Drain: 2 seconds X 12 times/day
1K ohms
2.8 mA @2.65V
Lithium Coin
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Typical Drains:
at 2.85V 
(mA)
0.064
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
ENERGIZER CR1220
Schedule:
Simulated Application test
Typical Performance at 21°C (70°F)
Continuous
Specifications
mm (inches)
Industry Standard Dimensions
United States:
Global (except US):
Cross Section
PRODUCT DATASHEET
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
100
200
300
400
500
600
700
V
o
lt
a
g
e
, CCV
Service, Hours
Load: 45K ohms - Continuous
Typical Drain @ 2.9V: 0.064 mA
40
80
120
160
200
240
280
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
5
10 15 20 25 30 35 40 45 50
IR,
 o
h
m
s
V
o
lt
a
g
e
, CCV
Capacity, mAh
IR
Pulse
Bkgnd
1-800-383-7323 USA/CAN
www.energizer.com
2.00 (0.079)
1.80 (0.071)
1.60 (0.063) Ref.
1.40 (0.055) Ref.
12.25 (0.482)
12.50 (0.492)
4.00 (0.157)
Minimum
0.20 (0.008) Maximum Ref.
Permissible deflection from a flat.
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4113H
Page 1 of 1