Insys Modem 56k 4.1 m/UL 11-02-01-01-40.022 Manuale Utente
Codici prodotto
11-02-01-01-40.022
INSYS Modem 56k UL
Command Overview
Juni 05
23
Bottom side terminal:
Terminal
11
OUT1NC
Output 1 – normally closed
12 OUT1
Output
1
13
OUT1NO
Output 1 – normally open
14
OUT2NC
Output 2 – normally closed
15 OUT2
Output
2
16
OUT2NO
Output 2 – normally open
17
b2
Through phone line
18 b1
Phone
line
19 a1
Phone
line
OUT 1-NC
OUT 1
OUT 2-NC
OUT 2
OUT 2-NO
OUT 1-NO
b2
b1
a1
a2
Lin
e
RX+
RX-
TX+
TX-
Eth
e
rnet
20
19
11
12
13
14
15
16
17
18
11
12
13
14
15
16
17
18
19
20
20
a2
Through phone line
a1 and b1 are the incoming phone lines (e.g. outside line or private branch exchange).
a2 and b2 are used to connect a phone in series. In idle state, they are connected to a1
and b1 via a loop current connector. a2 and b2 are detached as soon as the modem uses
the line.
note:
a2 and b2 are used to connect a phone in series. In idle state, they are connected to a1
and b1 via a loop current connector. a2 and b2 are detached as soon as the modem uses
the line.
note:
a2 and b2 are for the connection of a following telephone equipment. This tele-
phone equipment should be certified accordant UL 60950-1 part 6. Using only
cable Typ AWG26.
phone equipment should be certified accordant UL 60950-1 part 6. Using only
cable Typ AWG26.
5.2.3 Power Supply
Power supply:
10…60 V DC
Power consumption:
approx. 2,5 W (with connection)
Current consumption:
Supply voltage Current (idle) current (connection) max . power-up current
10 VDC
200 am
240 mA
300 mA
24 VDC
100 mA
110 mA
150 mA
Note: The Power Supply must always be secured with a UL LISTED Fuse Typ T5A H 250V.