Introduction 
Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC 
Voltage, DC Current, and Resistance testing. Proper use and care of this meter will provide 
many years of reliable service. 
Safety 
This symbol adjacent to another symbol, terminal or operating device 
indicates that the operator must refer to an explanation in the Operating 
Instructions to avoid personal injury or damage to the meter. 
This WARNING symbol indicates a potentially hazardous situation, which 
if not avoided, could result in death or serious injury. 
This CAUTION symbol indicates a potentially hazardous situation, which 
if not avoided, may result damage to the product. 
This symbol advises the user that the terminal(s) so marked must not be 
connected to a circuit point at which the voltage with respect to earth 
ground exceeds 600VAC or VDC. 
This symbol adjacent to one or more terminals identifies them as being 
associated with ranges that may, in normal use, be subjected to 
particularly hazardous voltages. For maximum safety, the meter and its 
test leads should not be handled when these terminals are energized. 
This symbol indicates that a device is protected throughout by double 
insulation or reinforced insulation. 
 
 
 
 
SAFETY INSTRUCTIONS 
This meter has been designed for safe use, but must be operated with caution. The rules 
listed below must be carefully followed for safe operation. 
1. 
NEVER
 apply voltage or current to the meter that exceeds the specified maximum: 
Input Protection Limits 
Function Maximum 
Input 
V DC or V AC 
600V AC and DC 200Vrms on the 200mV range 
mA DC 
200mA DC 250V fast acting fuse 
ADC 
10A 250V fast acting fuse  
(30 seconds max every 15 minutes) 
Resistance, Continuity 
250Vrms 15 seconds max 
2. 
USE EXTREME CAUTION
 when working with high voltages. 
3. 
DO NOT
 measure voltage if the voltage on the "COM" input jack exceeds 500V above 
earth ground. 
4. 
NEVER
 connect the meter leads across a voltage source while the function switch is in 
the current, resistance, or diode mode. Doing so can damage the meter. 
5. 
ALWAYS
 discharge filter capacitors in power supplies and disconnect the power when 
making resistance or diode tests. 
6. 
ALWAYS
 turn off power and disconnect test leads before opening the covers to replace 
the fuse or battery. 
7. 
NEVER
 operate the meter unless the back cover and the battery and fuse covers are in 
place and fastened securely. 
8. 
If the equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired. 
WARNING 
CAUTION 
MAX 