5.6  Send Messages 
Note: The sending time of an SMS from the sender to a recipi-
ent depends on the pertinent provider of the service 
number. Depending on the degree of utilization and 
the time of day, an SMS may be on the way for an 
extended period.
 
5.6.1  Transmission Configuration 
The modem can not only send the alarm message to another 
analogue modem, but also to a mobile phone as an SMS. Cur-
rently GSM900 and GSM1800, and SMS to fixed networks, fax 
and e-mail. 
The maximum text length is 160 characters. 
 
Protocol settings – see table - 
 
Transmission 
Protocol 
Data 
format 
Example 
 
Data Connection 
 
 
 AT*M0 
SMS to Mobile 
PET 
8N1 
D1 or   
E Network 
AT*M1 
SMS to Mobile 
UCP 
7E1 
 AT*M2 
SMS to Mobile 
PET 
7E1 
 AT*M3 
SMS to Mobile 
UCP 
8N1 
D2 network 
AT*M4 
Fax  
 
 AT*M5 
SMS to Mobile 
or Fixed Network 
 
 
 
AT*M6 
 
Enter the service number of the network provider to send 
SMS, or the phone number for fax and data connections 
 
Definition of the collective message 
 
Definition of the variable alarm texts and phone numbers to 
send SMS (alarm text 1 or 2). After this command is activated, 
the modem will query the alarm text.
 
AT*M<n> 
AT*V 
AT&Z0=<phone num-
ber> 
AT*V1 
AT*V2