Firmware Update 
INSYS Modem 56k small INT 2.0/USB 1.0  
42 
June 06
 
 
 
Close the window when the update is completed. 
 
 
 
8.2  Terminal Program 
8.2.1  Requirements 
For the firmware update, you will need a PC and a termi-
nal program. The terminal program must be able to per-
form an ASCII upload (ASCII data transmission protocol). 
Setting the hardware flow control is mandatory. For safety 
reasons, any interpretation of characters (e.g.: TAB, CR, 
BS...) by the ASCII upload protocol must be prevented. 
The baud rate must be between 9,600 baud and 57,600 
baud. Other baud rates may lead to errors. The loading 
procedure takes about 2 to 3 minutes for 57,600 baud; for 
lower baud rates accordingly longer. 
8.2.2  Activation and Process 
Start of the flash update  
 
The modem sends a response 
 
 
 
 
 
The update is performed in two steps: 
Download initiated… 
Transfer file with the help 
of the terminal program. 
AT**