10  S Registry 
S registries may be read and written using the ATS<n> command. (See Chapter 9 
"AT Command Set", command ATS<n>) Certain S registries may only be read; into 
others only a particular range of values may be entered.  
If the range of values is exceeded, the modem will report OK, although the value 
was not accepted. We therefore recommend to immediately check modifications 
by reading (ATS<n>?). 
 
Note: 
These registries are stored in the user defaults with AT&W0 or AT&W1. 
10.1 Overview S Registry 
Register 
Function 
Units 
Range 
Default 
S0* 
Number of ringing tones until automatically going off-
hook 
Ringing 
tones 
0-5 5 
S1 Ringing 
tone 
counter 
Ringing 
tones 
0-255 0 
S2* Escape 
ASCII 
0-255 43 
S3 Return 
ASCII 
0-127 13 
S4 Linefeed 
character 
ASCII 
0-127 10 
S5 Backspace 
character 
ASCII 
0-255 8 
S6* 
Waiting period dial tone 
4-7 
S7* 
Waiting period carrier signal 
0-100 
60 
S8* Dial 
tone 
delay 
1-7  2 
S9* 
Reaction time carrier signal 
0.1 s 
1-255 
S10* 
Time period between lost carrier signal and hang up 
0.1 s 
20-254 
20 
S12* 
Transmission clock of the ESC characters 
0.02 s 
0-255 
50 
S13* 
Number of dialing attempts to send the message 
 
1-12 
S14* General 
settings 
 
 
138 
S15* DTC 
Time 
Settings 
1s 
0-255  0* 
S17* 
Initial character for remote configuration 
 
0-127 
42 
S21* 
Settings for V24 
 
 
116 
S22* 
Speaker system settings 
 
 
75h (117) 
S24* 
Time period until switching into sleep mode 
0-255 
S25 
Time period for DTR signal 
0.01 s 
0-255 
S26 
Time period between RTS/CTS 
0.01 s 
0-255 
S27* General 
settings 
 
137 
S29 
Time period for modifier “Flash” 10 
ms 
17 
17