Useful Equations and Conversions 
Area equations 
The volume of air flowing through a duct or vent can be determined by taking the area of the duct 
in square units (i.e. square feet) and multiplying this value by the measured linear velocity (i.e., feet 
per minute). This gives: ft/min x ft
2
 = ft
3
/min (CFM) 
 
Cubic equations 
CFM (ft
3
/min) = Air Velocity (ft/min) x Area (ft
2
CMM (m
3
/min) = Air Velocity (m/sec) x Area (m
2
) x 60 
 
Units Conversion Table 
 
 m/s 
ft/min 
knots 
km/hr 
MPH 
1 m/s 
1 
196.85 
1.944 
3.6 
2.237 
1 ft/min 
0.00508 
1 
0.00987 
0.01829 
0.01136 
1 knot 
0.5144 
101.27 
1 
1.852 
1.151 
1 km/hr 
0.2778 
54.68 
0.54 
1 
0.6214 
1 MPH 
0.447 
88 
0.869 
1.6093 
1 
 
 
 
 
 
 
 
 