Test Limits
B
U2300A Series DAQ Service Guide
61
Ana
log Input
U2
33
1A
:
Of
fse
t/
Ga
in E
rror
 (
V
)
Setting
Range
 (V)
Te
st Poi
n
t (V)
Te
s
t L
im
it
 (
V
)
Te
st Resul
t
Pol
a
ri
ty
Min
Max
Loca
tion
Va
lu
e
Low
e
r
Upp
e
r
Reading
0.
00
15
UN
IP
0
10
Ce
nt
e
r FS
5.
00
00
0
4.
99
85
0
5.
00
15
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
4
UN
IP
0
10
Positiv
e
 FS
9.
90
23
4
9.
89
83
4
9.
90
63
4
DA
Q reading – O
ffse
t
0.0
0
4
UN
IP
0
10
Ne
ga
ti
ve FS
0.
09
76
6
0.
09
36
6
0.
10
16
6
DA
Q reading – O
ffse
t
0.
00
15
UN
IP
0
5
Ce
nt
e
r FS
2.
50
00
0
2.
49
85
0
2.
50
15
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
2
UN
IP
0
5
Positiv
e
 FS
4.
95
11
7
4.
94
91
7
4.
95
31
7
DA
Q reading – O
ffse
t
0.0
0
2
UN
IP
0
5
Ne
ga
ti
ve FS
0.
04
88
3
0.
04
68
3
0.
05
08
3
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
4
Ce
nt
e
r FS
2.
00
00
0
1.
99
85
0
2.
00
15
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.
00
15
UN
IP
0
4
Positiv
e
 FS
3.
96
09
4
3.
95
89
4
3.
96
29
4
DA
Q reading – O
ffse
t
0.
00
15
UN
IP
0
4
Ne
ga
ti
ve FS
0.
03
90
6
0.
03
70
6
0.
04
10
6
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
2.
5
Ce
nt
e
r FS
1.
25
00
0
1.
24
90
0
1.
25
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
2.
5
Positiv
e
 FS
2.
47
55
9
2.
47
40
9
2.
47
70
9
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
2.
5
Ne
ga
ti
ve FS
0.
02
44
1
0.
02
29
1
0.
02
59
1
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
2
Ce
nt
e
r FS
1.
00
00
0.
99
90
0
1.
00
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
2
Positiv
e
 FS
1.
98
04
7
1.
97
94
7
1.
98
14
7
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
2
Ne
ga
ti
ve FS
0.
01
95
3
0.
01
85
3
0.
02
05
3
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
1
Ce
nt
e
r FS
0.
50
00
0
0.
49
90
0
0.
50
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
1
Positiv
e
 FS
0.
99
02
3
0.
98
92
3
0.
99
12
3
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
1
Ne
ga
ti
ve FS
0.
00
97
7
0.
00
87
7
0.
01
07
7
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
5
Ce
nt
e
r FS
0.
25
00
0
0.
24
90
0
0.
25
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
0.
5
Positiv
e
 FS
0.
49
51
2
0.
49
41
2
0.
49
61
2
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
5
Ne
ga
ti
ve FS
0.
00
48
8
0.
00
38
8
0.
00
58
8
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
4
Ce
nt
e
r FS
0.
20
00
0
0.
19
90
0
0.
20
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
0.
4
Positiv
e
 FS
0.
39
60
9
0.
39
50
9
0.
39
70
9
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
4
Ne
ga
ti
ve FS
0.
00
39
1
0.
00
29
1
0.
00
49
1
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
1
Ce
nt
e
r FS
0.
05
00
0
0.
04
90
0
0.
05
10
0
O
ffset = 
DA
Q reading – Ca
librator source
 vol
ta
g
e
0.0
0
1
UN
IP
0
0.
1
Positiv
e
 FS
0.
09
90
2
0.
09
80
2
0.
10
00
2
DA
Q reading – O
ffse
t
0.0
0
1
UN
IP
0
0.
1
Ne
ga
ti
ve FS
0.
00
09
8
–0
.0
00
02
0.
00
19
8
DA
Q reading – O
ffse
t