Settings
CAN Baud rate
Possible settings: 
10kBd
20KBd
50kBd
100kBd
,
       
125kBd
250kBd
500kBd
1MBd
Default setting: 
100kBd
Belongs to: CAN interface card IF-C1
Explanation: determines the transmission speed of the 
CAN bus messages. If you connect the CAN card to an 
existing network, you got to set the same baudrate here 
as the bus is using, becaus any device in a bus has to 
use the same bus speed.
CAN ID System
(available since firmware 5.01)
Possible settings: 
normal, Vector
Default setting: 
normal
Belongs to: CAN interface card IF-C1
Explanation: with this, the user selects whether to use 
the 
normal
 CAN ID system with 2 IDs per unit or the new 
Vector
 compatible CAN ID system with 3 IDs per unit. With 
setting 
normal
, the two IDs per unit build from the 
Device 
node
 and the 
Relocatable ID
 (see external interface cards 
manual for calculation scheme). With setting 
Vector
, the 
device will be assigned three CAN IDs, starting from the 
base ID (see below), which is adjustable in steps of four 
withing the whole ID range (11 bits, 0...2047). An addi-
tional ID is assigned as broadcast ID, which is seperate 
from the three base IDs.
Note: depending on the setting being 
normal
 or 
Vector
subsequent parameters will change.
CAN Relocatable ID
Possible settings: 
0...31
Default setting: 
0
Belongs to: CAN interface card IF-C1
Explanation:  this  determines  the  relocatable  address 
segment in which the CAN IDs of the device are located. 
For further information refer to basic CAN topology datas-
heets. Example: if the electronic load has to be assigned 
to address 5 by certain reasons and this would collide 
with another bus member with the same address, you can 
move the address to another segment by defining the RID 
(short for relocatable ID), so that no collision can occur. 
Hence there are, theoretically, 32 x 30 possible device 
nodes (with two IDs each) available when using CAN.
7.  Device configuration
7.1  The setup menu
The setup menu can only be activated by the selector 
Level(3), except during remote control. While the load is 
in setup, no normal load operation is possible.
The  display  shows  a  certain  number  of  parameters, 
depending on which interface card is installed. The para-
meters are selected by knob 
Selection(5) and changed 
with  knob 
Setting(6). Two small triangles on the right 
side of the display indicate that multiple parameters are 
available. The display furthermore shows the type string 
of the installed card in the first line, for example 
IF-U1
, if 
one is equipped:
Figure 14
The second line subsequently shows all available para-
meters which are selected by 
Selection(5). The number 
of parameters varies depending if an interface card is 
equipped or not. 
There are following settings:
Trigger mode
Possible settings: 
internal, external
Default setting: 
internal
Belongs to: Device
Explanation: defines, if the trigger signal for the Level A/B 
operation, which effects the change between A and B, is 
automatically generated by the device (
internal
) or if it‘s 
put in by the trigger input (
external
).
Keep set values
Possible settings: 
yes
no
Default setting: 
no
Belongs to: Device
Explanation: 
yes
defines, that the set values which are 
adjusted by the user are kept when switching the regu-
no 
defines, that the set values are always 
reset to default values when switching.
Device node
Possible settings: 
1
...
30
Default setting: 
1
Belongs to: Interface cards
Explanation: defines the device node (or address) of the 
device in order to distinct between multiple devices in 
a network and to address it correctly. Up to 30 devices 
can be controlled from one PC. Within a bus system like 
CAN or GPIB, every address must only be given once.