8. Lens Information 
 
 
 
 
9. Troubleshooting 
 
Q)  Cannot connect to the camera, SYNC always fails 
A)  Unplug the camera and plug it in again, try to SYNC again. If this fails, then the power supply you are 
using may have a slow rise time. Testing of power supplies with a rise time of under 5uS resulted in 
correct operation. Power supplies with a rise time of greater than about 50uS resulted in trouble to 
SYNC. Change your power supply and try again. 
 
Q)  Was connected to camera but now it won’t SYNC 
A)  Be sure you are doing the SYNC at the baud rate you were previously connected at. The uCAM-II will 
keep the baud rate which you had set until it is powered off. See section 5.4. If you still cannot 
connect, you may need to restart the camera with a power cycle. 
 
Q)  I am having trouble SYNC’ing with the uCAM-II 
A)  Please refer to Section 7.1 Note 1, and try this procedure to SYNC’ing. 
 
Q)  Cannot focus the camera on the target 
A)  Please refer to the table in section 8, and ensure you are using the correct lens for the distance to the 
object. Twist the lens in or out to adjust the focus, and secure using the lock nut. 
 
Q)  Camera no longer responding to Serial Commands 
A)  The uCAM-II will go to sleep after 15 seconds of sitting idle. Sending the SYNC Command will wake the 
camera from sleep, and will enable normal operation once again. 
 
Q)  Camera not responding to anything 
A)  In rare situations the uCAM-II may stop responding. Restarting the uCAM-II by powering off and on 
again should restore correct operation.