Analog Devices ADP2291 Evaluation Board ADP2291RM-EVALZ ADP2291RM-EVALZ Scheda Tecnica

Codici prodotto
ADP2291RM-EVALZ
Pagina di 20
  
ADP2291
 
Rev. A | Page 3 of 20 
SPECIFICATIONS 
V
IN
 = 5.5 V, V
BAT
 = 4.2 V, R
ADJ
 open, T
A
 = –40°C to +85°C, typical values are at 25°C, unless otherwise noted.
Table 1. 
Parameter 
Conditions  
Min  
Typ  
Max  
Unit  
POWER 
SUPPLY, 
IN 
 
  
  
Input Voltage 
 
4.5 
 
12 
Current Draw 
Fast charge/precharge/end-of-charge modes 
Timeout/shutdown/battery fault 
 

1.4 

1.8 
mA 
mA 
BATTERY 
VOLTAGE, 
BAT 
 
  
  
Voltage Accuracy, End-of-Charge (V
BAT, EOC
T
A
 = 0°C to +50°C 
V
IN
 = 4.5 V to 12 V 
V
IN
 – V
CS
 = VRS/10 
4.158 4.2  4.242 V 
Load Regulation, No Battery 
V
IN
 – V
CS
 = 0 to VRS
 
 −80 
 mV 
Current Draw 
Timeout mode, V
IN
 = 4.5 V to 12 V 
 
 
45 
µA 
Current Draw 
Battery fault/shutdown mode, V
IN
 = 4.5 V to 12 V 
 
0.1 
µA 
Reverse Leakage Current 
Power-down mode: V
IN
 = float, V
BAT
 = 4.2 V 
 
0.1 
 
µA 
FAST CHARGE MODE 
 
 
 
 
 
Sense Voltage Setpoint (VRS) 
V
IN
 – V
CS
, R
ADJ
 = open 
V
IN
 = 4.5 V to 12 V 
V
BAT
 = 3.6 V 
140 150 
160 mV 
Sense Voltage Setpoint (VRS) 
V
IN
 – V
CS
, R
ADJ
 = 100 kΩ 
V
IN
 = 4.5 V to 12 V 
V
BAT
 = 3.6 V 
40 50 
60 mV 
Current Regulation Adjustment 
Per V of (3 V – V
ADJ
 67 
 mV/V 
PRECHARGE 
MODE 
 
  
  
Sense Voltage Setpoint (VRS) 
V
IN
 – V
CS,
 R
ADJ
 = open 
V
IN
 = 4.5 V to 12 V 
V
BAT
 = 2 V 
10 15 
20 mV 
Sense Voltage Setpoint (VRS) 
V
IN
 – V
CS
, R
ADJ
 = 100 kΩ 
V
IN
 = 4.5 V to 12 V 
V
BAT
 = 2 V 
5 10 
15 
mV 
BAT Precharge Threshold 
V
BAT
 
rising 
2.65  
2.85 V 
Hysteresis 
 
 70 
 mV 
SHUTDOWN 
MODE 
 
 
  
  
ADJ Shutdown Threshold 
V
ADJ
 falling, V
IN
 = 4.5 V 
0.30 
 
0.45 
Hysteresis 
 
 40 
 mV 
Pull-Up Current from ADJ 
V
ADJ
 = 0 
 
40 
 
µA 
POWER-DOWN 
MODE 
 
  
  
V
IN
 Power-Down Threshold 
V
IN
 rising 
3.6 
 
Hysteresis 
 
 220 
 mV 
V
IN
_Good 
Comparator 
 
  
  
Threshold (V
IN
 > V
BAT
) V
IN
 
rising 
125 170 
220 mV 
Hysteresis 
 
 110 
 mV 
EOC 
COMPARATOR 
 
  
  
Current Threshold 
V
IN
 – V
CS
 falling, R
ADJ
 = open, relative to VRS 
10 
13 
Current Threshold 
V
IN
 – V
CS
 falling, R
ADJ
 = 100 kΩ, relative to VRS 
10 
16 
Hysteresis 
 
 12 
 mV 
RESTART 
COMPARATOR 
 
  
  
BAT Restart Threshold 
V
IN
 > 4.5 V, V
BAT
 falling, relative to V
BAT, EOC
−170  
 
mV