15.6.6 RTC Calendar Alarm Register
Name: RTC_CALALR
Address:
0xFFFFFEC4
Access: Read-write
• MONTH: Month Alarm
This field is the alarm field corresponding to the BCD-coded month counter.
• MTHEN: Month Alarm Enable
0 = The month-matching alarm is disabled.
1 = The month-matching alarm is enabled.
• DATE:  Date  Alarm
This field is the alarm field corresponding to the BCD-coded date counter.
• DATEEN: Date Alarm Enable
0 = The date-matching alarm is disabled.
1 = The date-matching alarm is enabled.
31
30
29
28
27
26
25
24
DATEEN
DATE
23
22
21
20
19
18
17
16
MTHEN
MONTH
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0