Infineon Technologies Hex-Half-Bridge / Double Six-Driver TLE 6208-6 G DEMOBOARD TLE 6208-6G DEMOBOARD TLE 6208-6G Scheda Tecnica
![Infineon Technologies](https://files.manualsbrain.com/attachments/cd4c1a804aaa58c9926930be19a3f960629763a6/common/fit/150/50/95fbeccd1750dbae7788601c921d35b81d8a3e7725579425d3d03dd9be82/brand_logo.gif)
Codici prodotto
DEMOBOARD TLE 6208-6G
TLE 6208-6 G
Data Sheet
19
2007-09-12
3
Timing Diagrams
Figure 4
Standard Data Transfer Timing
Standard Data Transfer Timing
Figure 5
Timing for Temperature Prewarning only
Timing for Temperature Prewarning only
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
0
14
13
12
11
10
9
8
7
6
5
4
3
2
1
15
DI
CLK
CSN
0
14
13
12
11
10
9
8
7
6
5
4
3
2
1
15
DO
CSN High to Low & rising edge of CLK: DO is enabled. Status information is transfered to Output Shift Register
CSN Low to High: Data from Shift-Register is transfered to Output Power Switches
previous Status
actual Data
DI: Data will be accepted on the falling edge of CLK-Signal
DO: State will change on the rising edge of CLK-Signal
_
_
__
_
_
_
_
_
_
_
_
_
_
_
_
_
_
time
1
0
0
0
1
1
+
+
new Data
actual Status
eg.
HS1
actual Data
old Data
DI
CLK
CSN
0
DO
CSN High to Low & CLK stays Low: Status information of Data Bit 0 ( Temperature prewarning )
is transfered to DO
is transfered to DO
DI: Data is not accepted
DO: Status information of Data Bit 0 ( Temperature prewarning ) will stay as long as CSN is low
time
_