The generic clock that will be configured must be written to the ID bit group (CLKCTRL.ID)
z
The generic clock generator used as the source of the generic clock must be written to the GEN bit group 
(CLKCTRL.GEN)
Refer to 
 register for details.
14.6.2.2  Enabling, Disabling and Resetting
The GCLK module has no enable/disable bit to enable or disable the whole module.
The GCLK is reset by writing a one to the Software Reset bit in the Control register (CTRL.SWRST). All registers in the 
GCLK will be reset to their initial state except for generic clocks and associated generators that have their Write Lock bit 
written to one. Refer to 
14.6.2.3  Generic Clock Generator
Each generic clock generator (GCLKGEN) can be set to run from one of eight different clock sources except 
GCLKGEN[1] which can be set to run from one of seven sources. GCLKGEN[1] can act as source to the other generic 
clock generators but can not act as source to itself. 
Each generic clock generator GCLKGEN[x] can be connected to one specific GCLK_IO[x] pin. The GCLK_IO[x] can be 
set to act as source to GCLKGEN[x] or GCLK_IO[x] can be set up to output the clock generated by GCLKGEN[x].
The selected source (GCLKGENSRC see 
) can optionally be divided. Each generic clock generator can be 
independently enabled and disabled.
Each GCLKGEN clock can then be used as a clock source for the generic clock multiplexers. Each generic clock is 
allocated to one or several peripherals.
GCLKGEN[0], is used as GCLK_MAIN for the synchronous clock controller inside the Power Manager. 
Figure 14-3. Generic Clock Generator
14.6.2.4  Enabling a Generic Clock Generator
A generic clock generator is enabled by writing a one to the Generic Clock Generator Enable bit in the Generic Clock 
Generator Control register (GENCTRL.GENEN).
14.6.2.5  Disabling a Generic Clock Generator
A generic clock generator is disabled by writing a zero to GENCTRL.GENEN. When GENCTRL.GENEN is read as zero, 
the GCLKGEN clock is disabled and clock gated.
14.6.2.6  Selecting a Clock Source for the Generic Clock Generator
Each generic clock generator can individually select a clock source by writing to the Source Select bit group in 
GENCTRL (GENCTRL.SRC). Changing from one clock source, A, to another clock source, B, can be done on the fly. If 
GCLK_IO[x]
DIVIDER
Clock
Gate
GCLKGEN[x]
Clock Sources
0
1
GENCTRL.DIVSEL
GENCTRL.GENEN
GENDIV.DIV
GENCTRL.SRC
GCLKGENSRC
GCLKGENSRC