SPI_Ethernet_24j600_getBytes
SPI_Ethernet_24j600_UserTCP
Prototype
sub  procedure  SPI_Ethernet_24j600_getBytes(dim  ptr  as  ^byte,  dim  addr  as 
word, dim n as word)
Description This is MAC module routine. It fetches equested number of bytes from 
ENC24J600
 RAM starting from 
given address. If value of 
0xFFFF
 is passed as the address parameter, the reading will start from 
current 
ENC24J600
 read pointer (
ERDPT
) location.
Parameters 
ptr
: buffer for storing bytes read from 
ENC24J600
 RAM. 
addr
: ENC24J600 RAM start address. Valid values: 
0..8192
n
: number of bytes to be read. 
Returns
Nothing.
Requires
Ethernet module has to be initialized. See SPI_Ethernet_24j600_Init.
Example
dim 
  buffer as byte[16] 
  ...
  SPI_Ethernet_24j600_getBytes(buffer, 0x100, 16) ‘ read 16 bytes, starting 
from address 0x100
Notes
None.
Prototype
sub function SPI_Ethernet_24j600_UserTCP(dim byref remoteHost as byte[4], 
dim remotePort as word, dim localPort as word, dim reqLength as word, dim 
byref flags as TEthJ600PktFlags) as word
Description This is TCP module routine. It is internally called by the library. The user accesses to the TCP request 
by using some of the SPI_Ethernet_24j600_get routines. The user puts data in the transmit buffer by 
using some of the SPI_Ethernet_24j600_put routines. The function must return the length in bytes of 
the TCP reply, or 0 if there is nothing to transmit. If there is no need to reply to the TCP requests, just 
define this function with return(0) as a single statement.
Parameters 
remoteHost
: client’s IP address. 
remotePort
: client’s TCP port. 
localPort
: port to which the request is sent. 
reqLength
: TCP request data field length. 
flags
: structure consisted of two bit fields :  
Copy Code To Clipboard 
structure TEthj600PktFlags
   dim canCloseTCP as boolean  ‘ flag which closes socket
   dim isBroadcast as boolean  ‘ flag which denotes that the IP package has 
been received via subnet broadcast address
end structure
Returns
0
 - there should not be a reply to the request. 
- Length of TCP reply data field - otherwise. 
Requires
Ethernet module has to be initialized. See SPI_Ethernet_24j600_Init.
Example
This function is internally called by the library and should not be called by the user’s code.
Notes
The function source code is provided with appropriate example projects. The code should be adjusted 
by the user to achieve desired reply.